AN IMPACT OF THE EFFICIENT FUNCTIONING OF THE VENTILATION AND AIR-CONDITIONING SYSTEM ON THERMAL COMFORT OF THE MEDICAL STAFF IN THE OPERATING ROOM

机译:通风和空调系统的有效功能对手术室医护人员热舒适性的影响

获取原文

摘要

Ventilation and air conditioning systems are necessary for developing proper parameters of indoor envi-ronment in operating rooms. The main task of ventilation and air conditioning in those specific areas consists in creating desirable temperature, reducing the number of microorganisms and the concen-trations of hazardous gases and substances in the air, as well as ensuring the proper direction of airflow. In Poland, indoor environment in operating rooms has to comply with the requirements set out in three regulations (Journal of Laws of 2002 No. 75, item 690, as amended, Journal of Laws of 2002 No. 217, item 1833, Journal of Laws of 2011 No. 31, item 158, as amended) and the document entitled "Guidelines for the design of general hospitals". Given insufficient accuracy of the abovementioned national documents, it is a common practice to use foreign standards, i.e. ASHRAE Standard 170-2013, DIN 1946-4: 2008 and FprCEN TR 16244: 2011. When considering the conditions for thermal comfort, it is important to bear in mind a close link between air flow velocity and air temperature. Air in the zone occupied by patients and medical staff must not cause the sensation of draft. Furthermore, air velocity should be sufficient to eliminate interference caused by the presence of people and other sources of heat. It should also reduce the turbulence level in the air in the operating room. Efficient functioning of ventilation and air conditioning was tested during treatments and operations carried out on three wards of a Warsaw hospital. Tests were performed with the participation of medical staff from various surgical units. They were asked to perform minor manual tasks to simulate work on the op-erating table, and to complete a questionnaire on subjective thermal sensation. The applied methodology is widely used during testing of general and local ventilation in public buildings. Air temperature, relative humidity, air flow supply and exhaust air from the operating room were deter-mined on the basis of VelociCalc 8360 and Testo 435 anemometers with a 3-function probe and 3 vane probes with the diameter of 16 mm, 60 mm and 100 mm. Throughout the study, microclimate conditions in the operating rooms were controlled by the EHA MM101 microclimate meter. Test results showed that the microclimate parameters met the requirements of the aforementioned documents. However, individual thermal sensations reported by the medical staff pointed to the lack of thermal comfort and, in extreme cases, e.g. when using lead aprons during operations, perception of the thermal environment as ‘very hot’. The efficiency and type of air distribution in operating rooms has a decisive effect on the results.
机译:通风和空调系统对于在手术室中建立室内环境的适当参数是必不可少的。在这些特定区域中,通风和空调的主要任务包括创造理想的温度,减少微生物的数量以及空气中有害气体和物质的浓度以及确保正确的气流方向。在波兰,手术室的室内环境必须符合三项法规中规定的要求(经修订的2002年第75号法律期刊,第690条法律,2002年第217号法律期刊,第1833号法律, 2011年第31号公约第158项(经修订)和题为“综合医院设计指南”的文件。鉴于上述国家文件的准确性不足,通常使用国外标准,例如ASHRAE标准170-2013,DIN 1946-4:2008和FprCEN TR 16244:2011。在考虑热舒适性条件时,重要的是要牢记空气流速和空气温度之间的紧密联系。患者和医护人员所在区域内的空气不得引起吃水的感觉。此外,空气速度应足以消除由于人员和其他热源的存在而造成的干扰。它还应减少手术室中空气的湍流度。在华沙医院三病房进行的治疗和手术过程中,测试了通风和空调的有效功能。在来自各个外科部门的医务人员的参与下进行了测试。他们被要求执行一些次要的手工任务,以模拟手术台上的工作,并完成一份关于主观热感的问卷。在公共建筑的一般和局部通风测试中,该应用方法被广泛使用。根据VelociCalc 8360和Testo 435风速计(带有3功能探针和3个叶片探针,直径分别为16 mm,60 mm和3 mm)确定空气温度,相对湿度,气流供应和来自手术室的废气。 100毫米在整个研究过程中,手术室中的小气候条件由EHA MM101小气候仪控制。测试结果表明,微气候参数符合上述文件的要求。但是,医务人员报告的个人热感表明缺乏热舒适性,在极端情况下,例如,温度过低,可能会导致身体不适。在操作过程中使用铅皮围裙时,将热环境感知为“非常热”。手术室中空气分配的效率和类型对结果具有决定性的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号