摘要

References(11) Cited-By(7) The instantaneous heat transfer coefficients in a scraped-film heat exchanger have been determined using the electrochemical technique for a two-bladed, 78.7mm I.D. exchanger. The time-averaged local heat transfer coefficients were found to agree fairly well with previous work of Azoory and Bott, though some variation in liquid flow rate was detected. The timeaveraged local Nusselt number was found to be represented by Nu=Q.15(Rer•Pr)1/2Reawwith a=(l-3.74×10-2N)/9. The variation of heat transfer coefficient with time was observed to be very different from that predicted by the accepted model for the phenomena based upon unsteady state conduction.
机译:参考文献(11)引用依据(7)刮膜式换热器中的瞬时传热系数已使用电化学技术确定了两片式内径为78.7mm的内径。交换器。发现时间平均局部传热系数与Azoory和Bott的先前工作相当吻合,尽管检测到液体流速有一些变化。发现时间平均局部Nusselt数由Nu = Q.15(Rer•Pr)1 / 2Reaw表示,a =(1-3.74×10-2N)/ 9。观察到传热系数随时间的变化与基于非稳态传导现象的公认模型所预测的相差很大。