首页> 外文期刊>Journal of Clinical and Experimental Investigations >The Infections of Cardiac Implantable Electronic Devices: Four Year Experience of the Center
【24h】

The Infections of Cardiac Implantable Electronic Devices: Four Year Experience of the Center

机译:心脏植入式电子设备的感染:该中心的四年经验

获取原文

摘要

Objective: Cardiac implantable electronic devices (CIED) have been increasingly used in recent years. The incidence of infection has ranged from 0.5 % to 12% in the literature. The purposes of this study was to investigate the frequency of CIED infection and to find the causes of infection.Patients and methods: Totally, 211 patients with CIED infection were retrospectively evaluated. For each patient, all the following data were recorded; age, sex, CIED type, accompanying diseases, complete blood count, serum biochemistry, echocardiographic findings and whether first implantation or replacement. In addition, wound culture, antibiotic regime, erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), glomerular filtration rate (GFR) and anticoagulation test results were recorded in infected patients.Results: CIED infection was detected in 18 of the 211 patients (8.5%). 15 cases developed infection following the first implantation (10%), and 3 cases after replacement (5%). Infection was detected within 60 days in 5 patients. CIED pocket cultures were positive in 12 patients (66.7%). 13 of 18 infected devices were removed (72.2%). Diabetes mellitus [Odds Ratio, OR: 4.56 (1.449-14.408)] (p=0.010), male sex [OR: 3.84 (1.034-14.232)] (p=0.045) and increasing age [OR: 0.96 (0.932-0.998)] (p=0.038) were found as significant independent variables on development of CIED; but, pacemaker, implantable cardioverter defibrillator and cardiac resynchronization were not independent variables [OR: 1.66 (0.469-5.929)] (p=0.43).Conclusions: Increasing age, male sex, diabetes mellitus were related to increased frequency of CIED infections. Identification of comorbid conditions prior to CIED implantations may be important in reducing risk of CIED infections.
机译:目的:心脏植入式电子设备(CIED)近年来已得到越来越多的使用。文献中感染的发生率在0.5%至12%之间。这项研究的目的是调查CIED感染的频率并找出感染的原因。患者和方法:回顾性评估211例CIED感染患者。对于每个患者,记录以下所有数据;年龄,性别,CIED类型,伴随疾病,全血细胞计数,血清生化,超声心动图检查结果以及是否首次植入或置换。此外,还记录了感染患者的伤口培养,抗生素治疗,红细胞沉降率(ESR),C反应蛋白(CRP),肾小球滤过率(GFR)和抗凝试验结果。 211名患者(8.5%)。首次植入后有15例发生感染(10%),置换后有3例(5%)。 5例患者在60天内检测到感染。 CIED袋培养阳性12例(66.7%)。删除了18个受感染设备中的13个(72.2%)。糖尿病[赔率,或:4.56(1.449-14.408)](p = 0.010),男性[OR:3.84(1.034-14.232)](p = 0.045)和年龄增长[OR:0.96(0.932-0.998) ](p = 0.038)被认为是CIED发展的重要独立变量;但是,起搏器,植入式心脏复律除颤器和心脏再同步不是独立变量[OR:1.66(0.469-5.929)](p = 0.43)。结论:年龄,男性,糖尿病的增加与CIED感染频率的增加有关。植入CIED之前确定合并症可能对降低CIED感染的风险很重要。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号