首页> 外文期刊>Journal of Advanced Pharmaceutical Technology Research >Development, validation of liquid chromatography-tandem mass spectrometry method for simultaneous determination of rosuvastatin and metformin in human plasma and its application to a pharmacokinetic study
【24h】

Development, validation of liquid chromatography-tandem mass spectrometry method for simultaneous determination of rosuvastatin and metformin in human plasma and its application to a pharmacokinetic study

机译:液相色谱-串联质谱法同时测定人血浆中瑞舒伐他汀和二甲双胍的开发,验证及在药代动力学研究中的应用

获取原文
       

摘要

A new, simple and accurate liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous determination of rosuvastatin (ROS) and metformin (MET) in human plasma was developed. The assay procedure involved simple protein precipitation with acetonitrile. Following precipitation, fraction of supernatant was decanted and evaporated under gentle stream of nitrogen at 40°C. The residue was reconstituted in mobile phase and injected. The chromatographic separation was achieved with Thermo Hypurity C18 column (50 mm × 4.6 mm, 5 μ) using a mobile phase composition containing 0.1% v/v formic acid in water and acetonitrile (30:70, v/v) at a flow rate of 0.4 mL/min. The total run time was 3.5 min. The method showed good linearity in the range 0.5–200 ng/mL for ROS and 2–2000 ng/mL for MET with correlation coefficient (r) >0.9994 for both the analytes. The intra and inter-day precision values for ROS and MET met the acceptance criteria as per regulatory guidelines. The battery of stability studies viz., bench-top, freeze-thaw and long term stability were performed. The developed method was applied to a pharmacokinetic study.Keywords: Liquid chromatography-tandem mass spectrometry, metformin, method validation, pharmacokinetics, rosuvastatin
机译:建立了一种同时测定人血浆中瑞舒伐他汀(ROS)和二甲双胍(MET)的简便,准确的液相色谱-串联质谱(LC-MS / MS)新方法。测定步骤包括用乙腈进行简单的蛋白质沉淀。沉淀后,将上清液的一部分倾析并在40℃的温和氮气流下蒸发。残余物在流动相中重构并注入。使用含有0.1%v / v甲酸的水和乙腈(30:70,v / v)的流动相组合物,通过Thermo Hypurity C18色谱柱(50 mm×4.6 mm,5μ)进行色谱分离0.4 mL / min。总运行时间为3.5分钟。该方法对ROS的线性范围在0.5–200 ng / mL,对MET的线性范围在2–2000 ng / mL,显示出良好的线性,两种分析物的相关系数(r)> 0.9994。 ROS和MET的日内和日间精度值符合监管准则的验收标准。进行了稳定性研究,包括台式,冻融和长期稳定性研究。关键词:液相色谱-串联质谱法,二甲双胍,方法验证,药代动力学,瑞舒伐他汀

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号