Background. Cellulite is a type of lipodystrophy that develops primarily from an alteration in blood circulation or of the lymphatic system that causes structural changes in subcutaneous adipose tissue, collagen, and adjacent proteoglycans. The radiofrequency devices used for cutaneous applications have shown different physiological treatment effects, but there is controversy about the suitable parameters for this type of treatment.Objectives. The aim of this study was to evaluate the effects of low-temperature radiofrequency to confirm the thinning of the collagen tissue and interlobular septa and consequent improvement of cellulite.Methods. A sample of eight women was used to collect ultrasonographic data with a 12 MHz probe that measured collagen fiber thickness. The Vip Electromedicina (Argentina) device, frequency of 0.55 MHz and active electrode 3.5 cm in diameter (area = 9.61 cm2), was applied to a 10 cm2region of the gluteal region for 2 minutes per area of active electrode, during 10 biweekly sessions.Results. The Wilcoxon matched paired test was applied using GraphPad InStat 3.01 for Win95-NT software. Pre- and posttreatment mean collagen fiber thickness showed a 24.66% reduction from 1.01 to 0.67 mm. Statistical analysis using the Wilcoxon matched paired test obtained a significant two-tailedPvalue of 0.0391.Conclusion. It was concluded that the use of more comfortable temperatures favored a reduction in fibrous septum thickness and consequent cellulite improvement, evidenced by the lower degree of severity and decrease in interlobular septal thickness.
机译:背景。橘皮组织是一种脂肪营养不良,主要由血液循环或淋巴系统改变引起,这种改变引起皮下脂肪组织,胶原蛋白和邻近蛋白聚糖的结构变化。用于皮肤应用的射频设备显示出不同的生理治疗效果,但是对于此类治疗的合适参数存在争议。这项研究的目的是评估低温射频的作用,以确认胶原组织和小叶间隔的变薄以及脂肪团的改善。八名妇女的样本被用来通过测量胶原纤维厚度的12 MHz探头收集超声数据。 Vip Electromedicina(Argentina)装置的频率为0.55 andMHz,有源电极的直径为3.5(cm(面积= 9.61 cm2),在10个双周疗程中,在每个有源电极区域的10 cm2区域的每一个有源电极区域施加2分钟。结果。使用适用于Win95-NT的GraphPad InStat 3.01进行Wilcoxon匹配配对测试。治疗前后,胶原纤维的平均厚度从1.01mm减少到0.67mm,减少了24.66%。使用Wilcoxon配对配对检验进行的统计分析得出显着的两尾P值为0.0391。结论。结论是,使用更舒适的温度有利于减少纤维间隔厚度并因此改善脂肪团,这由较低的严重程度和小叶间间隔厚度的减少所证明。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号