Background The purpose of this study was to assess the extent to which a supplemental radiographic view increases accuracy and confidence ratings when determining screw placement in volar plating of distal radius fractures for evaluators of different specialties and experience levels. Methods Thirty-four distal radius fractures treated with volar plate fixation were imaged using standard AP and lateral, and supplemental lateral tilt views. Each case was then evaluated for penetration of distal screw tips into the articular space. Sixty-five physicians then completed a two-phase analysis and survey of these cases. In the first phase, presentation consisted only of AP and lateral views; in the second, the lateral tilt view was added. Participants were asked to determine whether distal screws penetrated the joint and rate their confidence in the determination. Assessments were scored for correctness; changes in accuracy and confidence levels between phases were analyzed using paired t tests. Comparisons between groups were performed by ANOVA. Results Supplementation increased accuracy and confidence in all position, specialty, and experience groups. Confidence scores were significantly higher following evaluation of three views versus two views. Residents exhibited the greatest improvements in accuracy and confidence. For first-phase (standard view) assessments, accuracy scores were significantly better for attendings with less than 10 years post-fellowship experience than those with more. Conclusions A supplemental view of the distal radius combined with AP and lateral views significantly improves the ability of all evaluators, regardless of specialty or training level, to correctly assess placement of fixation screws. The greatest improvements are seen for resident trainees.
机译:背景技术这项研究的目的是评估为不同专业和经验水平的评估者确定radius骨远端骨折掌侧钢板中螺钉放置时,补充放射线照相术能提高准确性和置信度的程度。方法对34例经掌侧钢板固定治疗的radius骨远端骨折,采用标准AP和侧面及补充侧面倾斜图进行成像。然后评估每种情况下远端螺钉尖端是否穿透到关节间隙中。然后,六十五名医生完成了对这些病例的两阶段分析和调查。在第一阶段,演示仅包含AP和侧视图。在第二个中,添加了横向倾斜视图。要求参与者确定远端螺钉是否穿透关节并评估其信心。对评估的正确性进行评分;使用配对t检验分析了相之间准确性和置信度的变化。各组之间的比较通过ANOVA进行。结果补充提高了对所有职位,专业和经验组的准确性和信心。评估三种观点后的置信度得分明显高于两种看法。居民在准确性和信心方面表现出最大的进步。对于第一阶段(标准视图)评估,与研究后经验少于10年的参加者相比,准确性得分明显更高。结论远端radius骨的补充视图与AP和侧面视图相结合,可显着提高所有评估者的能力,无论其专业水平或培训水平如何,均可正确评估固定螺钉的位置。对于驻地培训生来说,最大的进步是看到的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号