首页> 外文期刊>The Open Ophthalmology Journal >Evaluation of Preloaded IOL Delivery System and Hydrophobic Acrylic Intraocular Lens in Cataract Surgery
【24h】

Evaluation of Preloaded IOL Delivery System and Hydrophobic Acrylic Intraocular Lens in Cataract Surgery

机译:白内障手术中预装人工晶状体输送系统和疏水性丙烯酸人工晶状体的评价。

获取原文
       

摘要

Background:Advancements in cataract surgery have necessitated the availability of intraocular lens preloaded delivery systems that can safely, effectively and predictably deliver IOLs in the eye. Preloaded delivery systems simplify and reduce procedural variability during surgery preparation.Objective:The objective of this study was to evaluate clinical acceptability, delivery characteristics and clinical outcomes in patients implanted with new generation hydrophobic acrylic Intraocular Lens with Preloaded delivery system.Methods:This was a single centre retrospective study. Total 41 patients were enrolled in the study to get at least 38 patients for evaluation. All patients were assessed on day1 and 1, 3 and 6 months after surgery.Results:EYECRYL-SERT showed ‘excellent’ ease of insertion and handling in all 41(100%) patients. Corrected Distance Visual Acuity (CDVA) improved from 0.74±0.58 logMAR during screening to 0.03±0.04 logMAR 6 months after surgery. The Corrected Intermediate Visual Acuity (CIVA) and Corrected Near Visual Acuity (CNVA) were 0.10±0.04 and 0.01±0.02 logMAR post 6 months surgery, respectively. The refractive spherical equivalence was -1.94±2.51 D during screening, which improved significantly (p=0.0018) to -0.21±0.47 D post 6 months surgery. The low and high contrast sensitivity was 0.06±0.06 and -0.05±0.06 logMAR after 6 months surgery, respectively. The endothelial cell loss was 5.67%, 7.22% and 9.75% at 1, 3, and 6 months after surgery, respectively, as compared to screening. None of the subjects reported any adverse event during the study period.Conclusion:The IOL delivery system (EYECRYL_SERT) provided desired delivery characteristics during cataract surgery and was effective in improving clinical outcomes in cataract patients.
机译:背景:白内障手术的发展已使眼内晶状体预装递送系统的可用性成为可能,该系统可以安全,有效和可预测地将IOL递送至眼内。预载分娩系统简化并减少了手术准备过程中的程序变异性。目的:本研究的目的是评估植入有预载分娩系统的新一代疏水性丙烯酸丙烯酸人工晶状体的患者的临床可接受性,分娩特征和临床结局。单中心回顾性研究。共有41位患者参与了研究,至少获得38位患者进行评估。在手术后的第1天,1、3和6个月对所有患者进行了评估。结果:EYECRYL-SERT在所有41(100%)患者中均显示出“极好的”插入和操作便利性。矫正视力(CDVA)从筛查时的0.74±0.58 logMAR提高到术后6个月的0.03±0.04 logMAR。术后6个月的矫正中视力(CIVA)和矫正近视力(CNVA)分别为0.10±0.04和0.01±0.02 logMAR。筛选期间的屈光球当量为-1.94±2.51 D,在术后6个月后显着改善(p = 0.0018)至-0.21±0.47D。术后6个月,低和高对比敏感度分别为0.06±0.06和-0.05±0.06 logMAR。与筛查相比,术后1、3和6个月的内皮细胞损失分别为5.67%,7.22%和9.75%。研究期间没有受试者报告任何不良事件。结论:IOL输送系统(EYECRYL_SERT)在白内障手术期间提供了所需的输送特性,并有效改善了白内障患者的临床结局。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号