PURPOSE pCement-retained implant prostheses can lack proper retrievability during repair, and residual cement can cause peri-implantitis. The purpose of this in vitro study was to evaluate the influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with lingual slots, known as retrievable cement-type slots (RCS). MATERIALS AND METHODS pWe fabricated six types of titanium abutments (10 of each type) with two different heights (4 mm and 6 mm), three different convergence angles (8°, 10°, and 12°), a sloped shoulder margin (0.6 mm depth), a rectangular shape (6 mm × 6.5 mm) with rounded edges, and a rectangular ledge (2 mm × 1 mm) for the RCS. One monolithic zirconia crown was fabricated for each abutment using a dental computer-aided design/computer-aided manufacturing system. The abutments and crowns were permanently cemented together with dual-curing resin cement, followed by 24 hours in demineralized water at room temperature. Using a custom-made device with a slot driver and torque gauge, we recorded the torque (N·cm) required to remove the crowns. Statistical analysis was conducted using multiple regression analysis and Mann-Whitney U tests (α=.05). RESULTS pRemoval torques significantly decreased as convergence angles increased. Multiple regression analysis showed no significant interaction between the abutment height and the convergence angle (Durbin-Watson ratio: 2.186). CONCLUSION pWithin the limitations of this in vitro study, we suggest that the retrievability of cement-retained implant prostheses with RCS can be maintained by adjusting the abutment height and convergence angle, even when they are permanently cemented together.
机译:目的保留水泥的植入物假体在修复过程中可能缺乏适当的可回收性,残留的水泥会引起种植体周围炎。这项体外研究的目的是评估基台高度和会聚角对带有舌缝的水泥固位假体的可回收性的影响,这种假牙被称为可回收水泥型缝(RCS)。材料与方法>我们制造了六种类型的钛基台(每种类型的10种),它们具有两个不同的高度(4 mm和6 mm),三个不同的会聚角(8°,10°和12°),倾斜的肩部边缘(0.6毫米深度),矩形(6毫米×6.5毫米)和圆角边缘,以及用于RCS的矩形壁架(2毫米×1毫米)。使用牙科计算机辅助设计/计算机辅助制造系统为每个基台制作了一个整体式氧化锆冠。将基台和牙冠与双固化树脂胶粘剂永久粘合在一起,然后在室温下于软化水中放置24小时。使用带有槽驱动器和扭矩计的定制设备,我们记录了移除表冠所需的扭矩(N·cm)。使用多元回归分析和Mann-Whitney U检验(α= .05)进行统计分析。结果>随着会聚角的增加,去除扭矩显着降低。多元回归分析显示,基台高度和会聚角之间没有显着的相互作用(Durbin-Watson比:2.186)。结论>在这项体外研究的局限性内,我们建议即使通过将基台高度和会聚角永久固定在一起,也可以通过调整基台高度和会聚角来保持采用RCS的水泥固位假体的可恢复性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号