首页> 外文期刊>The Journal of Advanced Prosthodontics >Evaluation of marginal fit of 2 CAD-CAM anatomic contour zirconia crown systems and lithium disilicate glass-ceramic crown
【24h】

Evaluation of marginal fit of 2 CAD-CAM anatomic contour zirconia crown systems and lithium disilicate glass-ceramic crown

机译:评估2个CAD-CAM解剖学轮廓氧化锆冠和二硅酸锂玻璃陶瓷冠的边缘拟合

获取原文
           

摘要

PURPOSE This study was to evaluate the marginal fit of two CAD-CAM anatomic contour zirconia crown systems compared to lithium disilicate glass-ceramic crowns. MATERIALS AND METHODS Shoulder and deep chamfer margin were formed on each acrylic resin tooth model of a maxillary first premolar. Two CAD-CAM systems (Prettau?Zirconia and ZENOSTAR?ZR translucent) and lithium disilicate glass ceramic (IPS e.max?press) crowns were made (n=16). Each crown was bonded to stone dies with resin cement (Rely X Unicem). Marginal gap and absolute marginal discrepancy of crowns were measured using a light microscope equipped with a digital camera (Leica DFC295) magnified by a factor of 100. Two-way analysis of variance (ANOVA) and post-hoc Tukey's HSD test were conducted to analyze the significance of crown marginal fit regarding the finish line configuration and the fabrication system. RESULTS The mean marginal gap of lithium disilicate glass ceramic crowns (IPS e.max?press) was significantly lower than that of the CAD-CAM anatomic contour zirconia crown system (Prettau?Zirconia) ( P CONCLUSION The lithium disilicate glass ceramic crown (IPS e.max?press) had significantly smaller marginal gap than the CAD-CAM anatomic contour zirconia crown system (Prettau?Zirconia). In terms of absolute marginal discrepancy, the CAD-CAM anatomic contour zirconia crown system (ZENOSTAR?ZR translucent) had under-extended margin, whereas the CAD-CAM anatomic contour zirconia crown system (Prettau?Zirconia) and lithium disilicate glass ceramic crowns (IPS e.max?press) had overextended margins.
机译:目的本研究旨在评估两个CAD-CAM解剖轮廓氧化锆冠系统与二硅酸锂玻璃-陶瓷冠系统相比的边缘拟合。材料与方法在上颌第一前磨牙的每个丙烯酸树脂牙齿模型上形成肩和深倒角边缘。制作了两个CAD-CAM系统(Prettau?Zirconia和ZENOSTAR?ZR半透明)和二硅酸锂玻璃陶瓷(IPS e.max?press)牙冠(n = 16)。每个牙冠都用树脂水泥(Rely X Unicem)粘结到石模上。使用配备有放大倍数为100的数码相机(Leica DFC295)的光学显微镜测量冠的边缘间隙和绝对边缘差异。进行了方差的双向分析(ANOVA)和事后Tukey HSD测试,以分析关于终点线配置和制造系统的胎冠边缘配合的重要性。结果二硅酸锂玻璃陶瓷冠(IPS e.max?press)的平均边缘间隙显着低于CAD-CAM解剖轮廓氧化锆冠系统(Prettau?Zirconia)(P结论二硅酸锂玻璃陶瓷冠(IPS e.max?press)的边缘间隙明显小于CAD-CAM解剖轮廓氧化锆冠系统(Prettau?Zirconia)。就绝对边际差异而言,CAD-CAM解剖轮廓氧化锆冠系统(ZENOSTAR?ZR半透明)边缘延伸不足,而CAD-CAM解剖学轮廓氧化锆冠系统(Prettau?Zirconia)和二硅酸锂玻璃陶瓷冠(IPS e.max?press)具有过度延伸的边缘。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号