首页> 外文期刊>Universidad Nacional de Colombia. Facultad de Medicina. Revista >Consistencia interna de la bater?-a de evaluaci?3n propioceptiva en personas con amputaci?3n transtibial (BEPAT) en el Hospital Militar Central
【24h】

Consistencia interna de la bater?-a de evaluaci?3n propioceptiva en personas con amputaci?3n transtibial (BEPAT) en el Hospital Militar Central

机译:中央军事医院经胫截肢术(BEPAT)患者本体感受评价电池的内部一致性

获取原文
           

摘要

Introduction: Several clinical trials are designed to assess proprioception, however, none of them has sufficient validity to be used in amputee population. For this reason, the Kinesiotherapy Research Group from Universidad Nacional de Colombia has developed a proprioceptive test battery for below-knee amputation (BEPAT) with prosthetics. This research evaluates the internal consistency of the battery. Objective: To establish the internal consistency of a proprioceptive test battery (BEPAT) in a group of amputees treated at Hospital Militar Central. Materials and methods: Cross-sectional study which involved 12 male subjects (100%) (aged 25.4 ?± 4.23) with transtibial amputation caused by landmine, and pin locking prosthesis (75%). Participants attended the prosthesis and amputees service at Hospital Militar Central between June and July 2014, meeting the criteria for inclusion in the study. Internal consistency was assessed with Cronbach's alpha (α). Results: BEPAT has a high internal consistency reliability, with a total alpha coefficient value of α=0.758. This value, for the domains of effector activities, kinesthesia and statesthesia, was (α=-0.264), (α=0.829) and (α=0.763), respectively. Conclusions: It was determined that BEPAT may be applicable in a clinical setting, obtaining in a high Cronbach's of α=0.758 during the first tests of reliability. The variables that comprise the domains have a positive influence on the internal consistency of the entire battery, and qualifications for the amputated leg are reduced, reporting values below 26, which indicates a regular proprioceptive response.
机译:简介:设计了一些临床试验来评估本体感受,但是,没有一项具有足够的有效性可用于截肢者。因此,哥伦比亚国立大学的Kinesiotherapy研究小组开发了一种用于假肢的膝下截肢术(BEPAT)的本体感受测试电池。这项研究评估了电池的内部一致性。目的:确定在Militar Central医院接受治疗的一组截肢者中本体感受测试电池(BEPAT)的内部一致性。材料和方法:横断面研究涉及12名男性受试者(100%)(年龄为25.4±4.23岁),由地雷造成的胫骨截肢和针固定假体(占75%)。参与者于2014年6月至7月期间参加了Militar Central医院的假肢和截肢服务,符合纳入研究的标准。内部一致性用Cronbach's alpha(α)评估。结果:BEPAT具有很高的内部一致性可靠性,总α系数值为α= 0.758。对于效应子活动,运动感觉和状态感觉而言,该值分别为(α= -0.264),(α= 0.829)和(α= 0.763)。结论:已确定BEPAT可能适用于临床环境,在第一次可靠性测试中获得的高Cronbach值为α= 0.758。包含域的变量对整个电池的内部一致性具有积极影响,并且截肢腿的资格降低,报告值低于26,这表示定期的本体感受性反应。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号