首页> 外文期刊>Pesticidi i fitomedicina: Pesticides & Phytomedicine >Dissipation rate of acetamiprid in sweet cherries
【24h】

Dissipation rate of acetamiprid in sweet cherries

机译:甜樱桃中扑热息痛的消散率

获取原文
           

摘要

Degradation of acetamiprid in sweet cherry samples was evaluated at several intervals from the product application until the end of the pre-harvest interval. An orchard of sweet cherries located at Stepanovi?evo village near Novi Sad was used in this study. Acetamiprid was applied according to the manufacturer’s recommendation for protecting sweet cherries from their most important pests. Sweet cherry fruit samples were collected at eight intervals: immediately after acetamiprid application and 2, 4, 6, 8, 10, 12 and 14 days after application. The extraction of acetamiprid from sweet cherry samples was performed using a QuEChERS-based method. Determination was carried out using an HPLC-UV diode array detection system (Agilent 1100, United States) with an Agilent Zorbax Eclipse C18 column (50 mm ? 4.6 mm internal diameter, 1.8 μm particle size). The method was subjected to a thorough validation procedure. The recovery data were obtained by spiking blank sweet cherry samples at three concentration levels (0.1-0.3 mg/ kg), yielding 85.4% average recovery. Precision values expressed as relative standard deviation (RSD) were below 1.61% for the intraday precision. Acetamiprid showed linear calibrations from 0.05 to 2.5 μg/ml with correlation coefficient (R2) of 0.995%. The limit of detection and limit of quantification were found to be 5 μg/kg and 14 μg/kg, respectively. The validated method was applied in the analysis of acetamiprid in sweet cherry samples. During the study period, the concentration of acetamiprid decreased from 0.529 mg/kg to 0.111 mg/kg. The content of acetamiprid in sweet cherry samples at the end of the pre-harvest interval was below the maximum permissible level specified by the Serbian and EU MRLs. [Projekat Ministarstva nauke Republike Srbije, br. TR31038: Development of chemical methods for analysis of the insecticide acetamiprid]
机译:从产品施用到收获前间隔结束的几个时间间隔评估甜樱桃样品中对乙酰氨基酚的降解。这项研究使用了位于诺维萨德附近的Stepanovi?evo村的甜樱桃果园。根据制造商的建议使用了乙草胺,以保护甜樱桃免受最重要的害虫侵害。在八个间隔内收集甜樱桃果实样品:施用乙酰胺ami后立即以及施用后2、4、6、8、10、12和14天。使用基于QuEChERS的方法从甜樱桃样品中提取扑热息痛。使用HPLC-UV二极管阵列检测系统(Agilent 1100,美国)和Agilent Zorbax Eclipse C18色谱柱(内径50 mm×4.6 mm,粒径1.8μm)进行测定。该方法经过了彻底的验证程序。通过以三种浓度水平(0.1-0.3 mg / kg)加标空白甜樱桃样品获得回收率数据,平均回收率为85.4%。日内精度表示为相对标准偏差(RSD)的精度值低于1.61%。乙草胺显示线性校正范围为0.05至2.5μg/ ml,相关系数(R2)为0.995%。检出限和定量限分别为5μg/ kg和14μg/ kg。验证的方法用于甜樱桃样品中扑热息痛的分析。在研究期间,扑热息痛的浓度从0.529 mg / kg降至0.111 mg / kg。收获前间隔结束时,甜樱桃样品中对乙酰氨基酚的含量低于塞尔维亚和欧盟最大残留限量规定的最大允许水平。 [Projekat Ministarstva nauke Republike Srbije,br。 TR31038:分析杀虫剂乙酰胺的化学方法的开发]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号