Abstract This paper reports the development of an easy to use antibody microarray-based immunoassay platform for sensitive and selective duplex detection of {PSA} (prostate specific antigen) and hK2 (human kallikrein 2). Using {PDMS} wells in a 3 × 9 array on epoxy-coated glass slides 27 duplex immunoassays can be performed in parallel. Automated microarraying provided fast and reproducible antibody arraying in each assay well. To achieve highly sensitive and selective detection of each biomarker, we evaluated and optimized the density of each of the immobilized capture antibodies. The assay platform showed a limit of detection (LOD) of each biomarker (PSA and hK2) of less than 10 pg/mL and a dynamic range of 104–105 orders of magnitude. Neither the {PSA} nor the hK2 antibody array showed any cross-reaction against each others target proteins or other plasma proteins. These results emphasize the importance of density optimization of capture antibody on the surface in order to achieve a sensitive and selective multiplex immunoassay.
机译:摘要本文报道了一种易于使用的基于抗体微阵列的免疫测定平台的开发,该平台可用于{PSA}(前列腺特异抗原)和hK2(人激肽释放酶2)的敏感和选择性双链检测。使用在环氧树脂涂层载玻片上以3×9阵列排列的{PDMS}孔,可以并行执行27次双重免疫测定。自动化微阵列技术可在每个测定孔中提供快速且可重复的抗体阵列。为了实现每种生物标记物的高灵敏度和选择性检测,我们评估并优化了每种固定化捕获抗体的密度。分析平台显示每种生物标志物(PSA和hK2)的检出限(LOD)小于10 pg / mL,动态范围为104-105个数量级。 {PSA}和hK2抗体阵列均未显示出针对彼此的靶蛋白或其他血浆蛋白的任何交叉反应。这些结果强调了表面上捕获抗体密度优化的重要性,以实现灵敏和选择性的多重免疫测定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号