Background: Tetrabenazine was approved in the year of 2008 by USFDA. It was indicated mainly as an antipsychotic drug but now-a-days it is used for the treatment of hyperkinetic disorders. Objective: The objective of the study was to develop a simple and cost-effective spectrophotometric methods for the determination of tetrabenazine in tablets. Materials and Methods: The UV-Visible spectrophotometric studies carried out by Shimadzu UV 1800 with UV probe software and FT-IR studies using bruker alpha with opus software. The UV spectrum at 284 nm (Method A) and visible spectrum at 454 nm (Method B) are recorded. The FT-IR band of carbonyl group in tetrabenazine appeared at 1700 cm?1 with two-point baseline between 1650-1750 cm?1 (Method C). Results: Method A: The UV method was proved linear over the range of 10–50 μg/mL with correlation coefficient r2=0.9988 and mean recovery of 99.02% to 101.54%. Method B: The colorimetric method involves oxidative reaction of tetrabenazine and it yields green color chromogen. The linear concentrations over the range of 3-15 μg/mL with correlation coefficient of r2=0.9981 and mean recovery of 99.93% to 100.50%. Method C: The FT-IR method was showed linear over the range of 5-25 μg/mg, with correlation coefficient r2=0.9998 and mean recovery of 100.75% to 100.91%. The results of tetrabenazine tablets showed good agreement with their label claim. The results of ANOVA declare there was no significant difference between these spectrophotometric methods. Conclusion: Hence, these spectroscopic methods can be used for routine quality testing analysis of tetrabenazine in pharmaceutical laboratories.
机译:背景:四苯那嗪在2008年获得了USFDA的批准。它主要被指示为抗精神病药,但如今它被用于治疗运动过度症。目的:本研究的目的是开发一种简单且经济高效的分光光度法测定片剂中丁苯那嗪。材料和方法:Shimadzu UV 1800使用UV探针软件进行的UV-可见分光光度研究,以及使用bruus alpha和opus软件进行的FT-IR研究。记录在284 nm处的UV光谱(方法A)和在454 nm处的可见光谱(方法B)。丁苯那嗪中羰基的FT-IR谱带出现在1700 cm?1处,两点基线在1650-1750 cm?1之间(方法C)。结果:方法A:证明UV方法在10–50μg/ mL范围内是线性的,相关系数r2 = 0.9988,平均回收率为99.02%至101.54%。方法B:比色法涉及丁苯那嗪的氧化反应,产生绿色色原。线性浓度在3-15μg/ mL范围内,相关系数r2 = 0.9981,平均回收率为99.93%至100.50%。方法C:FT-IR方法在5-25μg/ mg范围内呈线性,相关系数r2 = 0.9998,平均回收率100.75%至100.91%。丁苯那嗪片的结果与其标签声明吻合良好。方差分析的结果表明,这些分光光度法之间没有显着差异。结论:因此,这些光谱方法可用于制药实验室中丁苯那嗪的常规质量测试分析。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号