首页> 外文期刊>Korean journal of radiology : >Gadoxetic Acid (Gd-EOB-DTPA)-Enhanced MRI versus Gadobenate Dimeglumine (Gd-BOPTA)-Enhanced MRI for Preoperatively Detecting Hepatocellular Carcinoma: an Initial Experience
【24h】

Gadoxetic Acid (Gd-EOB-DTPA)-Enhanced MRI versus Gadobenate Dimeglumine (Gd-BOPTA)-Enhanced MRI for Preoperatively Detecting Hepatocellular Carcinoma: an Initial Experience

机译:牛ado酸(Gd-EOB-DTPA)增强MRI与加巴地酸二聚葡胺(Gd-BOPTA)增强MRI在术前检测肝细胞癌的初步经验

获取原文
           

摘要

Objective This study was designed to compare the diagnostic performance of gadoxetic acid-enhanced magnetic resonance imaging (MRI) with gadobenate dimeglumine-enhanced MRI for preoperatively detecting hepatocellular carcinoma (HCC). Materials and Methods Eighteen consecutive patients (17 men and one woman, age range: 31-73 years) with 22 HCCs underwent examinations with gadoxetic acid enhanced MRI and gadobenate dimeglumine-enhanced MRI on a 3.0-Tesla unit. The diagnosis of HCC was established after surgical resection and pathological conformation. Three observers independently reviewed each MR image in a random order on a tumor-by-tumor basis. The diagnostic accuracy of these techniques for the detection of HCC was assessed by performing an alternative free-response receiver operating characteristic (ROC) analysis. The sensitivity and positive predictive values were evaluated. Results The average value of the area under the ROC curve (Az) for gadoxetic acid enhanced MRI (0.887) was not significantly different from the Az (0.899) for gadobenate dimeglumine-enhanced MRI ( p > 0.05). The overall sensitivities of gadoxetic acid enhanced MRI and gadobenate dimeglumine-enhanced MRI were 80% and 83%, respectively, with no significant difference ( p > 0.05). The differences of the positive predictive values for the two contrast agents for each observer were not statistically significant ( p > 0.05). Conclusion The diagnostic performance of gadoxetic acid-enhanced MRI and gadobenate dimeglumine-enhanced MRI for preoperatively detecting HCC is quite similar.
机译:目的本研究旨在比较葡萄糖酸增强磁共振成像(MRI)和葡萄糖酸二聚葡萄糖胺增强MRI对术前检测肝细胞癌(HCC)的诊断性能。材料与方法连续18例22例HCC患者(17例男性和1例女性,年龄范围:31-73岁)接受了3.0特斯拉(Tesla)装置上的牛ado酸增强MRI和加多贝酸二聚葡胺增强MRI检查。肝癌的诊断是通过手术切除和病理学检查确定的。三位观察者在逐个肿瘤的基础上以随机顺序独立查看每个MR图像。这些技术检测HCC的诊断准确性通过执行替代的自由响应接收器工作特性(ROC)分析进行了评估。评估敏感性和阳性预测值。结果葡萄糖酸增强的MRI的ROC曲线下面积(Az)的平均值(0.887)与葡萄糖酸加二甲双胍增强的MRI的Az平均值(0.899)没有显着差异(p> 0.05)。鹿ado酸增强MRI和g酸倍他加二甲双胍增强MRI的总体敏感性分别为80%和83%,差异无统计学意义(p> 0.05)。对于每个观察者,两种造影剂的阳性预测值的差异无统计学意义(p> 0.05)。结论葡萄糖增强的MRI和葡萄糖酸的二聚氨基葡萄糖增强的MRI在术前检测肝癌中的诊断性能相当。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号