To develop a calibration curve for induction of dicentric chromosomes by radiation, we have used a 60Co gamma-ray source with dose rate of 12.5 mGy/s. Whole blood from 15 healthy donors was collected. Whole blood from each donor was divided equally into 8 parts for exposing to supposedly physical doses 0, 0.30, 0.50, 1.00, 1.50, 2.00, 3.00 and 4.00 Gy for a independent calibration curve. Whole blood from 15 donors was used to calibrate dose – effect and statistical for general calibration curve. Using Poisson test (U-test) for the distribution of dicentric chromosomes in the metaphases to determine the uniformity of the radiation field. The average from 15 independent calibration curves of linear correlated coefficient was determined to be r (y, d) = 0.5136 ± 0.0038. The model equation derived is y = aD + bD2 + C. The calibration equation of dose-effect was y = 1.01D + 4.43D2 + 0.56.
机译:为了开发通过辐射诱导双中心染色体的校正曲线,我们使用了剂量率为12.5 mG​​y / s的60Co伽玛射线源。收集了来自15位健康捐献者的全血。将每个供体的全血平均分为8个部分,以暴露于假定的物理剂量0、0.30、0.50、1.00、1.50、2.00、3.00和4.00 Gy,以获得独立的校准曲线。来自15个捐献者的全血用于校准剂量-效果和统计的总体校准曲线。使用泊松检验(U检验)确定中期中双着丝粒的分布,以确定辐射场的均匀性。线性相关系数的15条独立校准曲线的平均值确定为r(y,d)= 0.5136±0.0038。推导的模型方程为y = aD + bD2 +C。剂量效应的校准方程为y = 1.01D + 4.43D2 + 0.56。