Study of inter- and intra-observer reproducibility in the interpretation of [18F]choline PET/CT examinations in patients suffering from biochemically recurrent prostate cancer following curative treatment

机译:观察者之间和观察者内部再现性对治愈性治疗后生化性复发前列腺癌患者[18F]胆碱PET / CT检查解释的研究

获取原文

摘要

Background The aim of this study was to investigate the reproducibility of intra- and inter-observer interpretation of [18F]choline positron emission tomography/computed tomography examinations in patients suffering from biochemically recurrent prostate cancer following curative treatment. Methods A total of 60 patients with biochemical recurrence after curative treatment were included in this bicentric study. The interpretations were based on a systematic analysis of several anatomic regions and all the four nuclear medicine physicians used identical result consoles. The examinations were interpreted with no knowledge of the patients' clinical context. Two months later, a second interpretation of all these examinations was performed using the same method, in random order. Results To evaluate local recurrences, when the prostate is in place, the results showed moderate inter- and intra-observer reproducibility: concordance of all 4 physicians has a Fleiss' kappa coefficient of 0.553 with a confidence interval of (0.425 to 0.693). For patients who had had a prostatectomy, there was excellent concordance for the negative examinations. For the lymphatic basin, inter- and intra-observer reproducibility was excellent with a Fleiss' kappa coefficient of 0.892 with a confidence interval of (0.788 to 0.975). The lymphatic sub-group analysis was also good. For the lymphatic groups in the right or left hemi-pelves, all Fleiss' kappa and Cohen's kappa coefficients are varying from 0.760 to 1 with narrow confidence intervals from (0.536 to 0.984) to (1 to 1) in favour of good/excellent inter-observer reproducibility. To evaluate bone metastasis, inter-observer reproducibility was good with a Fleiss' kappa coefficient of 0.703 and a confidence interval of (0.407 to 0.881). Conclusion Our study is at time the only one on the reproducibility of interpretation of [18F]choline positron emission tomography/computed tomography examinations, which is a key examination for the treatment of patients suffering biochemical recurrence of prostate cancer. Interpretation of the [18F]choline positron emission tomography/computed tomography examination is not so useful at prostate level in patients not previously treated with prostatectomy but has a great interest on patients treated by prostatectomy. It showed good concordance in the interpretation of sub-diaphragmatic lymphatic recurrences as well as in bone metastasis.
机译:背景技术这项研究的目的是研究治愈性治疗后生化性复发性前列腺癌患者对[18F]胆碱正电子发射断层扫描/计算机断层扫描检查的观察者内和观察者间解释的可重复性。方法这项双中心研究共纳入60例治愈后生化复发的患者。解释基于对几个解剖区域的系统分析,所有四位核医学医师均使用相同的结果控制台。解释检查时不了解患者的临床情况。两个月后,使用相同的方法,以随机顺序对所有这些检查进行了第二次解释。结果为了评估局部复发,当前列腺就位时,结果显示观察者之间和观察者之间具有中等再现性:所有4位医师的一致意见的Fleiss kappa系数为0.553,置信区间为(0.425至0.693)。对于进行前列腺切除术的患者,阴性检查的一致性极好。对于淋巴盆,观察者之间和观察者之间的重复性极好,Fleiss kappa系数为0.892,置信区间为(0.788至0.975)。淋巴亚组分析也很好。对于右半骨或左半骨的淋巴组,所有Fleiss卡帕系数和Cohen卡帕系数均在0.760至1之间变化,从(0.536至0.984)到(1至1)较窄的置信区间,以支持良好/良好的交互作用。 -观察者可重复性。为了评估骨转移,观察者之间的可重复性良好,Fleiss kappa系数为0.703,置信区间为(0.407至0.881)。结论我们的研究是当时唯一关于[18F]胆碱正电子发射断层显像/计算机断层显像检查解释的可重复性的研究,这是治疗前列腺癌生化复发患者的关键检查。对于先前未接受前列腺切除术治疗的患者,[18F]胆碱正电子发射断层扫描/计算机断层扫描检查的解释在前列腺水平上不是很有用,但对经前列腺切除术治疗的患者非常感兴趣。在解释dia下淋巴结复发以及骨转移方面显示出良好的一致性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号