摘要

A simple and sensitive reversed phase high-performance liquid chromatographic (HPLC) method has been developed for the determination of catechin and epicatechin in cocoa powder and chocolates. The separation was achieved on a reversed phase C 18 column (TARGA) 5 μm by gradient elution with a flow rate of 1.0 mL/minute with an operating temperature of 30°C and detection with a UV-Visible detector was at 280 nm. The method was validated for linearity, precision, intra- and interday precision, and accuracy. The developed method is successfully applied for the determination of catechin and epicatechin content in chocolates. The Godiva brand chocolate contains high concentration of epicatechin.
机译:建立了一种简单灵敏的反相高效液相色谱(HPLC)方法,用于测定可可粉和巧克力中的儿茶素和表儿茶素。在5 C的反相C 18色谱柱(TARGA)上以5μm的梯度进行洗脱,流速为1.0μmL/分钟,工作温度为30°C,UV-Visible检测器的检测波长为280μnm。验证了该方法的线性,精度,日内和日间精度以及准确性。该方法成功用于巧克力中儿茶素和表儿茶素的含量测定。 Godiva品牌巧克力含有高浓度的表儿茶素。