Abstract Spasticity is a common pathological phenomenon in clinical practices, frequently expressed as a stroke, multiple sclerosis or cerebral palsy. The accurate quantification of spasticity allows early action to prevent the potentially irreversible consequences. The aim of this work is to develop and implement a mechatronic device for the accurate quantification of spasticity, which is able to differentiate spasticity from other motor disorders. The proposed method is based on the quantification of the tonic stretch reflex threshold (TSRT) for the assessment of the range of motion of the limb affected by spasticity. In order to validate the developed device, experimental trials have been conducted, considering the flexor muscle of the elbow joint. The developed device was tested, first in a laboratory environment with healthy subjects and secondly, in a clinical environment with the collaboration of patients with spasticity. The evaluations in th clinical environment were performed on three different ...
机译:摘要痉挛是临床上常见的病理现象,常表现为中风,多发性硬化或脑瘫。对痉挛症的准确量化可以及早采取行动,以防止潜在的不可逆转的后果。这项工作的目的是开发和实现一种用于精确定量痉挛的机电设备,该设备能够将痉挛与其他运动障碍区分开。所提出的方法基于强直拉伸反射阈值(TSRT)的量化,以评估受痉挛影响的肢体的运动范围。为了验证开发的装置,已经进行了考虑肘关节屈肌的实验性试验。首先在健康受试者的实验室环境中测试其开发的设备,其次在患有痉挛性患者的临床环境中对其进行测试。在临床环境中的评估是在三种不同的方式下进行的。