Objectives: To describe the risks of ureteral damage occurring during urological and gynecological procedures utilizing energybased surgical devices (ESD) during both laparoscopic and open procedures. Materials and Methods: During the last 20 months we observed five cases of iatrogenic ureteral lesions caused by ESD which required open surgery. There were 3 lesions of the lower ureter occurring during gynecological laparoscopic or robotic procedures, and 2 lesions of the upper ureter occurring during open enucleation of low-stage renal cell carcinomas. Results: In the laparoscopic gynecological lesions the cause was attributable to monopolar cutting and bipolar coagulation: they presented with urine extravasation after 20, 15 and 15 days respectively and required ureteral reimplantation in 2 out of 3 cases. In the upper ureteral lesions the causes were bipolar coagulation and LigaSure Impact TM used for perirenal fat dissection: they presented after 2 and 4 months respectively and required uretero-ureterostomy and inferior nephropexy in one case and nephrectomy in the other. In 3 out of 5 cases there was an unsuccessful attempt at placing an ureteral double J stent, and in the 2 cases where it was placed it did not prevent the formation of subsequent stricture in one. Conclusions: The widespread diffusion of ESD has the potential drawback of inadvertent thermal energy transmission to the ureter. Delayed presentation of ureteral lesions and difficulties in ureteral stent placement were the common features of the cases observed. Inadvertent ureteral damage by different thermal energy sources is an emerging condition, requiring awareness, prompt recognition and adequate treatment with the reconstructive urology principles.
机译:目的:描述在腹腔镜和开放式手术过程中使用基于能量的外科手术器械(ESD)在泌尿科和妇科手术中发生输尿管损伤的风险。材料和方法:在最近的20个月中,我们观察到5例由ESD引起的医源性输尿管病变,需要进行开放手术。在妇科腹腔镜或机器人手术中,下输尿管有3个病变,在低期肾细胞癌的开放摘除术中有2个上输尿管的病变。结果:在腹腔镜妇科病变中,原因可归因于单极切割和双极凝结:他们分别在20、15和15天后出现尿液渗出,在3例中有2例需要输尿管再植。在输尿管上段病变中,原因是双极电凝和将LigaSure Impact TM用于肾周脂肪解剖:它们分别在2个月和4个月后出现,一例需要输尿管-输尿管造口术和下肾切除术,另一例需要肾切除术。在五分之三的病例中,未尝试置入输尿管双J支架,在放置的2例病例中,未阻止一次合并形成狭窄。结论:ESD的广泛传播具有无意间将热能传递到输尿管的潜在缺点。输尿管病变的延迟呈现和输尿管支架置入困难是观察到的病例的共同特征。不同热源对输尿管造成的无意损害是一种新出现的状况,需要认识,迅速认识并以重建泌尿科原则进行适当治疗。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号