Objective: Development and validation of a RP-HPTLC method coupled with densitometry analysis for the determination of BHT as such and in commercial food sample (Butter). Methods: Chromatographic separation of BHT was achieved by employing a mobile phase consisting of Methanol – Water (9.5:0.5) on precoated aluminium TLC plates, silica gel RP-18 F254sand UV densitometric quantitative evaluation was performed by measuring the absorbance reflectance of the analyte spots at 254?nm. Results: The BHT was satisfactorily resolved with R f value 0.48 ± 0.02. The study was carried out in the range of 500 ng to 5000 ng. The LOQ and LOD for BHT were 0.524 and 0.157 ng respectively. The method was validated with respect to linearity, repeatability, specificity, accuracy (recovery) and precision. Conclusion: The proposed method has high degree of repeatability and will provide fast and cost-effective quantitative control for routine analysis of BHT as single and in food sample.
机译:目的:RP-HPTLC方法的开发和验证,以及光密度分析法可用于测定商业食品样品(黄油)本身中的BHT。方法:通过在预涂铝TLC板上使用甲醇-水(9.5:0.5)组成的流动相,硅胶RP-18 F254色谱柱和通过测量分析物斑点的吸光度反射率进行的紫外光度定量评估,对BHT进行色谱分离在254纳米。结果:BHT令人满意,R f值为0.48±0.02。该研究在500 ng至5000 ng的范围内进行。 BHT的LOQ和LOD分别为0.524和0.157 ng。该方法在线性,重复性,特异性,准确性(回收率)和精密度方面得到了验证。结论:该方法具有高度的重复性,可为常规的食品样品中BHT的常规分析提供快速,经济高效的定量控制。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号