A reliable determination of zinc levels in beverages with and without alcohol by flame atomic absorption spectrometry after cloud point extraction

机译:浊点萃取后通过火焰原子吸收光谱法可靠地测定含酒精和不含酒精的饮料中的锌含量

获取原文
           

摘要

Cloud point extraction (CPE) has been used for the preconcentration and quantification of zinc after the formation of a stable complex with N-phenylbenzohydroxamic acid (PBHA) at pH 9.0 and analysis by flame atomic absorption spectrometry (FAAS) using polyethylene glycol tert-octylphenyl ether (Triton X-114) as the extracting surfactant. The chemical variables affecting the phase separation and the viscosity affecting the detection process were optimized. A preconcentration of only 50 mL of sample in the presence of 0.02% (w/v) Triton X-114 and 2.0 ?— 10a?’4 mol La?’1 PBHA permitted the detection and quantification of 0.42 and 1.41 ??g La?’1 zinc, respectively. The improvement and preconcentration factors were 74.2 and 50 for zinc, respectively. The accuracy was controlled by analysis of the certified reference materials, SRM 1515 and SRM 1573a. The obtained results were in good agreement with the certified values. The proposed method was successfully applied to the determination of trace levels of zinc in beverage samples with satisfactory results. The results of zinc determination in the digested samples with HNO3/H2O2 (3:1, v/v) are in agreement with that in the digested samples with HNO3/HClO4 (5:1, v/v). Zinc levels are in the range of 44.40a€“110.15 ??g La?’1 with standard deviation values ranging from 1.35 to 2.65 ??g La?’1 for the canned beverages without alcohol and 35.65a€“135.80 ??g La?’1 with standard deviation values ranging from 1.10 to 3.50 ??g La?’1 for the beverages with alcohol.
机译:浊点萃取(CPE)已用于在pH 9.0下与N-苯基苯并异羟肟酸(PBHA)形成稳定的络合物并通过火焰原子吸收光谱法(FAAS)使用聚乙二醇叔辛基苯基进行分析后对锌进行预浓缩和定量醚(Triton X-114)作为萃取表面活性剂。优化了影响相分离的化学变量和影响检测过程的粘度。在0.02%(w / v)Triton X-114和2.0?-10a?'4 mol La?'1 PBHA的存在下,仅进行50mL样品的预浓缩就可以检测和定量0.42和1.41?g La分别为′′1锌。锌的改善因子和预浓缩因子分别为74.2和50。通过对认证参考材料SRM 1515和SRM 1573a的分析来控制准确性。所得结果与标准值吻合良好。该方法成功用于饮料样品中痕量锌的测定,结果令人满意。用HNO3 / H2O2(3:1,v / v)消解样品中锌的测定结果与用HNO3 / HClO4(5:1,v / v)消解样品中锌的测定结果一致。不含酒精的罐装饮料中锌的含量范围为44.40a·110.15 g La?1,标准偏差范围为1.35至2.65 g·g La?1,罐装饮料的锌含量为35.65a·135.80 g。含酒精饮料的La?'1标准偏差值为1.10到3.50 g g La?'1。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号