首页> 外文期刊>Journal of the Iranian Chemical Society >Application of ultrasonic-assisted cloud point extraction/flame atomic absorption spectrometry (UA-CPE/FAAS) for preconcentration and determination of low levels of antimony in some beverage samples
【24h】

Application of ultrasonic-assisted cloud point extraction/flame atomic absorption spectrometry (UA-CPE/FAAS) for preconcentration and determination of low levels of antimony in some beverage samples

机译:超声辅助浊点萃取/火焰原子吸收光谱法(UA-CPE / FAAS)在某些饮料样品中富集和测定低含量锑中的应用

获取原文
获取原文并翻译 | 示例
           

摘要

Due to be able to migrate or leach from food packaging materials into the foods and/or beverages, development of a new, sensitive and selective analytical methods for low levels of antimony as a food contaminant is of great importance in terms of food safety. In this context, an ultrasonic-assisted cloud point extraction method was developed for the preconcentration and determination of antimony as Sb(III) using 4-(2-thiazolylazo)resorcinol (TAR) and 2-(2-thiazolylazo)-p-cresol (TAC) as chelating agents and sodium dodecyl sulfate as signal enhancing agent at pH 6.0 and mediated by nonionic surfactant, t-octylphenoxypolyethoxyethanol by flame atomic absorption spectrometry. Using the optimized conditions, the calibration curves obtained from Sb(III) with TAR and TAC were linear in the concentration ranges of 0.5-180 and 1-180 mu g L-1 with detection limits of 0.13 and 0.28 mu g L-1, respectively. The precision (as relative standard deviations, RSDs) was lower than 3.9 % (25 and 100 mu g L-1, n: 6). The method accuracy was validated by the analysis of two standard reference materials. The results obtained were statistically in a good agreement with the certified values at 95 % confidence limit. The method has successfully been applied to the determination of Sb(III) and total Sb in selected beverages, milk and fruit-flavored milk products before and after pre-reduction of Sb(V) to Sb(III) with a mixture of KI/ascorbic acid in acidic media. The Sb(V) contents of samples were quantitatively calculated from analytical difference between total Sb and Sb(III) levels.
机译:由于能够从食品包装材料中迁移或浸出到食品和/或饮料中,因此对于食品安全而言,开发用于检测食品中锑含量低的锑的新的,灵敏的和选择性的分析方法非常重要。在这种情况下,开发了一种超声辅助浊点萃取方法,用于使用4-(2-噻唑基偶氮)间苯二酚(TAR)和2-(2-噻唑基偶氮)-对甲酚对锑进行Sb(III)的富集和测定。 pH值为6.0的非离子表面活性剂叔辛基苯氧基聚乙氧基乙醇的火焰原子吸收光谱法测定(TAC)作为螯合剂,十二烷基硫酸钠作为信号增强剂。在优化的条件下,用TAR和TAC从Sb(III)获得的校准曲线在0.5-180和1-180μgL-1的浓度范围内是线性的,检出限为0.13和0.28μgL-1,分别。精密度(相对标准偏差,RSD)低于3.9%(25和100μg L-1,n:6)。通过分析两种标准参考物质验证了方法的准确性。统计结果与95%置信限下的认证值在统计学上吻合良好。该方法已成功地用于测定KI / H2O3还原为Sb(V)之前和之后的特定饮料,牛奶和水果味奶制品中的Sb(III)和总Sb酸性介质中的抗坏血酸。根据总Sb和Sb(III)含量之间的分析差异定量计算样品的Sb(V)含量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号