Background :The indocyanine green (ICG) finger monitoring method is a newly developed noninvasive method for the ICG clearance test. This study was performed to determine its clinical usefulness compared with the conventional blood sampling method. Method :The ICG clearance test was performed on 270 patients using both the conventional blood sampling method and the finger monitoring method simultaneously. The plasma disappearance rate of the ICG and the 15-minute retention ratio (ICG R15) were analyzed and compared with the conventional blood sampling method. Result :The plasma disappearance rate using the finger monitoring method was slightly lower than that of the conventional blood sampling method with good correlation (r=0.840, P0.001). Conclusion :As there was a good correlation between the conventional blood sampling method and the finger monitoring method, the latter method seemed to be clinically useful due to its convenience and accuracy.
机译:背景:吲哚菁绿(ICG)手指监测方法是一种新开发的用于ICG清除测试的无创方法。进行这项研究是为了确定其与常规血液采样方法相比的临床实用性。方法:使用常规血液采样方法和手指监测方法同时对270例患者进行ICG清除测试。分析了ICG的血浆消失率和15分钟保留率(ICG R15),并与传统的血液采样方法进行了比较。结果:使用手指监测方法的血浆消失率略低于常规采血方法,相关性良好(r = 0.840,P <0.001)。结论:由于常规采血方法与手指监测方法之间具有良好的相关性,后一种方法由于其便利性和准确性似乎在临床上很有用。