A simple method for the determination of phytosterols such as β-sitosterol, campesterol, stigmasterol, and brassicasterol has been developed using high-performance liquid chromatography with electrochemical detection (HPLC-ECD). Under optimized conditions, the current peak height was linearly related to the amount of phytosterol injected, ranging from 10 to 200 μmol L?1 (r = 0.999). The relative standard deviation (RSD) was less than 3.1% (100 μmol L?1, n = 6). The detection limit (S/N = 3) of phytosterol was less than 3.4 μmol L?1 (17 pmol). Phytosterols spiked into the control human and rat sera were determined by the present method with recovery rates of more than 80% and RSDs (n = 3) of less than 4.2%. This method has been successfully applied to the monitoring of experimental phytosterolemia in rats induced by a high-phytosterol diet. Taken together, we found this method, which does not require a derivatization step, is both simple and useful for the simultaneous determination of serum phytosterols, providing an alternative tool for the diagnosis of phytosterolemia...
机译:使用高效液相色谱-电化学检测(HPLC-ECD)已开发出一种测定植物甾醇(例如β-谷甾醇,菜油甾醇,豆甾醇和芸苔甾醇)的简单方法。在最佳条件下,当前峰高与注入的植物甾醇量呈线性关系,范围为10至200μmolL?1(r = 0.999)。相对标准偏差(RSD)小于3.1%(100μmolL?1,n = 6)。植物甾醇的检出限(S / N = 3)小于3.4μmolL?1(17 pmol)。通过本方法测定掺入对照人和大鼠血清中的植物甾醇,其回收率大于80%,RSD(n = 3)小于4.2%。该方法已成功应用于监测高植物甾醇饮食诱导的大鼠实验性植物甾醇血症。综上所述,我们发现这种不需要衍生步骤的方法既简单又有用,可同时测定血清植物甾醇,为诊断植物甾醇血症提供了另一种工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号