首页> 外文期刊>AgroLife Scientific Journal >DETERMINATION OF HEATING REQUIREMENTS AND ENERGY CONSUMPTION OF GREENHOUSES IN ADANA REGION OF TURKEY
【24h】

DETERMINATION OF HEATING REQUIREMENTS AND ENERGY CONSUMPTION OF GREENHOUSES IN ADANA REGION OF TURKEY

机译:土耳其阿达纳州温室的供暖需求和能源消耗的测定

获取原文
       

摘要

In this study, the heating loads of plastic greenhouses were determined based on long term meteorological data inAdana region of Turkey. Considering the air temperature requirements of warm season species, energy consumptionswere calculated for heating periods. If the monthly average low temperatures are considered as the outside airtemperature, when the air temperature in the greenhouse is considered as in 18 C, the average greenhouse heatingload is 64.4 W/m2, during the October-May heating period. However, when the air temperature in the greenhouse isconsidered as in 15 C, the average greenhouse heating load is 44.5 W/m2 during the same period. The average energyconsumption for 1 da greenhouse heating (Tg=15 C) is 176 MJ/h, during the October-May heating period.
机译:在这项研究中,根据土耳其阿达纳地区的长期气象数据确定了塑料大棚的热负荷。考虑到暖季物种的气温要求,计算了供暖期的能耗。如果将每月平均低温视为外部气温,则将温室中的空气温度视为18°C时,在10月至5月的供暖期间,平均温室供暖负荷为64.4 W / m2。然而,当考虑温室中的空气温度为15°C时,同一时期的平均温室热负荷为44.5 W / m2。在10月至5月的供暖期间,每1 da温室供暖(Tg = 15 C)的平均能耗为176 MJ / h。