...
首页> 外文期刊>Advances in Interventional Cardiology: Postepy w Kardiologii Interwencyjnej >Short-term stent coverage of second-generation zotarolimus-eluting durable polymer stents: Onyx one-month optical coherence tomography study
【24h】

Short-term stent coverage of second-generation zotarolimus-eluting durable polymer stents: Onyx one-month optical coherence tomography study

机译:第二代佐他莫司洗脱耐久聚合物支架的短期支架覆盖:Onyx的一个月光学相干断层扫描研究

获取原文

摘要

Introduction To date the early strut coverage with the second-generation durable-polymer ONYX zotarolimus-eluting stent (O-ZES) is unknown. Aim Optical coherence tomography (OCT) assessed the strut coverage of O-ZES at thirty-day follow-up. Material and methods OCT was performed after implantation and at 1-month follow-up in 15 patients treated with O-ZES. Results Mean patient age was 67 ±7 years (73% males). The clinical presentation consisted of acute coronary syndromes (n = 13) and stable coronary disease (n = 2). Four (26%) patients had diabetes. OCT analysis was performed at baseline and 1-month follow-up in all stents. 378 cross-sections with 3582 struts were assessed at baseline and 3661 at follow-up. At follow-up, 88% struts were covered by tissue with a?median thickness 37.91?μm (IQR: 22.32–64.15). Median in-stent area obstruction by neointima was 2.64% (IQR: 1.70–4.84). From the total stent covered area, 92.3% showed complete strut coverage. Homogeneous tissue was observed in 74% of cases. There were no differences in minimal lumen area (5.07 ±1.08?mm2 vs. 4.81 ±0.94?mm2, p = 0.125) or minimal stent area (4.95 ±1.22?mm2 vs. 4.92 ±0.99?mm2) at baseline and at follow-up. There were no differences in the rate of strut malapposition (4.3% vs. 5.7%, p = 0.417). For all stents, malapposition volume was 47.9?mm3 at baseline and 51.7?mm3 at follow-up, giving the late acquired stent malapposition volume of 3.8?mm3. Conclusions The second-generation durable polymer O-ZES showed favorable vessel healing at 30-day OCT follow-up.
机译:引言迄今为止,尚不知道第二代耐用聚合物ONYX佐他莫司洗脱支架(O-ZES)的早期撑杆覆盖率。目的光学相干断层扫描(OCT)在30天的随访中评估了O-ZES的支杆覆盖率。材料和方法在植入后以及在1个月的随访中,对15例接受O-ZES治疗的患者进行了OCT。结果平均患者年龄为67±7岁(男73%)。临床表现包括急性冠状动脉综合征(n = 13)和稳定型冠心病(n = 2)。四(26%)例患有糖尿病。在所有支架的基线和1个月随访中进行了OCT分析。在基线时评估了378个横断面,具有3582个支撑,在随访时评估了3661个。在随访中,88%的支撑杆被组织覆盖,中间厚度为37.91?m(IQR:22.32–64.15)。新内膜对支架内区域的中位阻塞率为2.64%(IQR:1.70–4.84)。从支架总覆盖面积来看,有92.3%的支架完全覆盖。在74%的病例中观察到同质组织。在基线和随访时,最小管腔面积(5.07±1.08mm2 vs. 4.81±0.94mm2,p = 0.125)或最小支架面积(4.95±1.22mm2 vs. 4.92±0.99mm2)没有差异。向上。支杆畸形发生率无差异(4.3%vs. 5.7%,p = 0.417)。对于所有支架,基线时的贴壁不良体积为47.9?mm3,随访时为51.7?mm3,晚期获得的支架贴壁不良体积为3.8?mm3。结论第二代耐用聚合物O-ZES在OCT 30天随访中显示出良好的血管愈合。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号