首页> 外文期刊>European Heart Journal: The Journal of the European Society of Cardiology >Tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent vs. a fluoropolymer-coated everolimus-eluting stent at 13-month follow-up: an optical coherence tomography substudy from the RESOLUTE All Comers trial.
【24h】

Tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent vs. a fluoropolymer-coated everolimus-eluting stent at 13-month follow-up: an optical coherence tomography substudy from the RESOLUTE All Comers trial.

机译:在13个月的随访中,亲水聚合物涂层的佐他莫司洗脱支架与氟聚合物涂层的依维莫司洗脱支架的组织覆盖率:来自RESOLUTE All Comers试验的光学相干断层扫描研究。

获取原文
获取原文并翻译 | 示例
           

摘要

AIMS: To compare the tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent (ZES) vs. a fluoropolymer-coated everolimus-eluting stent (EES) at 13 months, using optical coherence tomography (OCT) in an 'all-comers' population of patients, in order to clarify the mechanism of eventual differences in the biocompatibility and thrombogenicity of the devices. METHODS AND RESULTS: Patients randomized to angiographic follow-up in the RESOLUTE All Comers trial (NCT00617084) at pre-specified OCT sites underwent OCT follow-up at 13 months. Tissue coverage and apposition were assessed strut by strut, and the results in both treatment groups were compared using multilevel logistic or linear regression, as appropriate, with clustering at three different levels: patient, lesion, and stent. Fifty-eight patients (30 ZES and 28 EES), 72 lesions, 107 stents, and 23 197 struts were analysed. Eight hundred and eighty-seven and 654 uncovered struts (7.4 and 5.8%, P= 0.378), and 216 and 161 malapposed struts (1.8 and 1.4%, P= 0.569) were found in the ZES and EES groups, respectively. The mean thickness of coverage was 116 +/- 99 microm in ZES and 142 +/- 113 microm in EES (P= 0.466). No differences in per cent neointimal volume obstruction (12.5 +/- 7.9 vs. 15.0 +/- 10.7%) or other areas-volumetric parameters were found between ZES and EES, respectively. CONCLUSION: No significant differences in tissue coverage, malapposition, or lumen/stent areas and volumes were detected by OCT between the hydrophilic polymer-coated ZES and the fluoropolymer-coated EES at 13-month follow-up.
机译:目的:使用“光学相干断层扫描”(OCT)技术,比较13个月时亲水性聚合物涂层的佐他莫司洗脱支架(ZES)和氟聚合物涂层的依维莫司洗脱支架(EES)的组织覆盖率为了阐明患者的生物相容性和血栓形成性最终差异的机理。方法和结果:在RESOLUTE All Comers试验(NCT00617084)中,在预先指定的OCT部位进行血管造影随访的患者在13个月时进行了OCT随访。通过支撑物评估组织覆盖率和并置物,并使用多级逻辑或线性回归对两个治疗组的结果进行比较,并在三个不同的水平上进行聚类:患者,病变和支架。分析了58例患者(30 ZES和28 EES),72个病变,107个支架和23 197个支杆。在ZES和EES组中,分别发现了877个未覆盖的支撑杆(7.4和5.8%,P = 0.378),以及216个和161个错位支撑杆(1.8和1.4%,P = 0.569)。 ZES的平均覆盖厚度为116 +/- 99微米,EES的平均覆盖厚度为142 +/- 113微米(P = 0.466)。在ZES和EES之间,未发现新内膜体积阻塞百分比(12.5 +/- 7.9与15.0 +/- 10.7%)或其他区域的差异。结论:在13个月的随访中,亲水聚合物涂层ZES和含氟聚合物涂层EES之间的OCT结果在组织覆盖率,贴壁不良或管腔/支架面积和体积上均无显着差异。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号