首页> 外文期刊>Advances in Interventional Cardiology: Postepy w Kardiologii Interwencyjnej >Neointima development in externally stented saphenous vein grafts
【24h】

Neointima development in externally stented saphenous vein grafts

机译:内支架大隐静脉移植物中的新内膜发展

获取原文
           

摘要

Introduction : The main limitation of coronary artery bypass grafting (CABG) is rapid neointimal hyperplasia leading to graft failure. Aim : To assess plaque formation in saphenous vein grafts (SVG) covered by an external Dacron stent in comparison with the classical technique. Material and methods : In the study group vein grafts covered by external stent mesh made of Dacron were implanted. An intravascular ultrasonography (IVUS) study was performed in 35 aorto-coronary SVG covered by an external Dacron stent and in 64 normal SVG during the first year after CABG. In each SVG 25 mm of good quality IVUS image, volumes of lumen, plaque (neointima), outer border of the vein graft (external SVG) and adventitia were calculated in three time periods: 0–130 days, 130–260 days and 260–390 days. Results : Between the first and second time period, lumen volume (mm3) was reduced from 10.33 ±4.4, to 6.80 ±2.23 in the second period and 5.69 ±1.26 in the third one. This effect was much less marked in normal grafts. The corresponding lumen volume (mm3) was: 10.90 ±3.9, 9.15 ±2.94 and 8.92 ±2.93 in consecutive time periods. Plaque volume (mm3) did not change in control grafts during the course of the study, but it increased very significantly in stented grafts from 0.86 ±1.24 in the first period to 2.70 ±1.58 in the second and 3.29 ±2.66 in the third one. Conclusions : The experimental technique of implanting SVG covered with an external elastic Dacron stent seems to be inferior to traditional ones. This is probably due to the more complicated process of vein implantation and higher micro-injury occurrence during the surgery.
机译:简介:冠状动脉搭桥术(CABG)的主要局限性是快速的内膜增生导致移植失败。目的:与传统技术相比,评估由外部Dacron支架覆盖的大隐静脉移植物(SVG)中的斑块形成。材料和方法:在研究组中,植入由Dacron制成的外部支架网覆盖的静脉移植物。在CABG术后的第一年,对35例由外部Dacron支架覆盖的主动脉冠状SVG和64例正常SVG进行了血管内超声(IVUS)研究。在每个质量为25 mm的高质量IVUS SVG图像中,在以下三个时间段内计算管腔,斑块(新内膜),静脉移植物的外部边界(外部SVG)和外膜的体积:0-130天,130-260天和260天–390天。结果:在第一个和第二个时间段之间,管腔体积(mm3)从10.33±4.4减小到第二个周期的6.80±2.23,第三个周期的5.69±1.26。在正常的移植物中,这种作用不明显。在连续的时间段中,相应的管腔体积(mm 3)为:10.90±3.9、9.15±2.94和8.92±2.93。在研究过程中,对照移植物中的斑块体积(mm3)没有变化,但覆膜支架移植物中的斑块体积却显着增加,从第一阶段的0.86±1.24上升到第二阶段的2.70±1.58和第三阶段的3.29±2.66。结论:植入体外弹性Dacron支架覆盖的SVG的实验技术似乎不如传统技术。这可能是由于静脉植入过程更加复杂,并且在手术过程中发生了更多的微损伤。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号