首页> 外文期刊>Actuators >Modeling the Static Force of a Festo Pneumatic Muscle Actuator: A New Approach and a Comparison to Existing Models
【24h】

Modeling the Static Force of a Festo Pneumatic Muscle Actuator: A New Approach and a Comparison to Existing Models

机译:Festo气动肌肉执行器的静态力建模:一种新方法以及与现有模型的比较

获取原文

摘要

In this paper, a new approach for modeling the static force characteristic of Festo pneumatic muscle actuators (PMAs) will be presented. The model is physically motivated and therefore gives a deeper understanding of the Festo PMA. After introducing the new model, it will be validated through a comparison to a measured force map of a Festo DMSP-10-250 and a DMSP-20-300, respectively. It will be shown that the error between the new model and the measured data is below 4.4% for the DMSP-10-250 and below 2.35% for the DMSP-20-300. In addition, the quality of the presented model will be compared to the quality of existing models by comparing the maximum error. It can be seen that the newly introduced model is closer to the measured force characteristic of a Festo PMA than any existing model.
机译:在本文中,将介绍一种用于建模Festo气动肌肉执行器(PMA)静态力特性的新方法。该模型是出于物理动机,因此可以更深入地了解Festo PMA。引入新模型后,将通过与Festo DMSP-10-250和DMSP-20-300的测得力图进行比较来验证该模型。可以看出,对于DMSP-10-250,新模型与测量数据之间的误差低于4.4%,而对于DMSP-20-300,误差则低于2.35%。另外,通过比较最大误差,可以将提出的模型的质量与现有模型的质量进行比较。可以看出,与现有模型相比,新引入的模型更接近于Festo PMA的测得力特性。