首页> 外文期刊>Computer Assisted Surgery >Novel method for setting up 3D navigation system with skin-fixed dynamic reference frame in anterior cervical surgery
【24h】

Novel method for setting up 3D navigation system with skin-fixed dynamic reference frame in anterior cervical surgery

机译:颈前路皮肤固定动态参考架建立3D导航系统的新方法

获取原文
           

摘要

Purpose : To introduce easy and useful methods using 3D navigation system with skin-fixed dynamic reference frame (DRF) in anterior cervical surgery and to validate its accuracy.Methods : From September 2012 to May 2013, 31 patients underwent anterior cervical surgery and a total of 48 caspar distraction pins were inserted into each cervical vertebra. Every operation was performed using O-arm? navigation system with skin-fixed DRF. To validate the accuracy of these methods, a custom-made metal sleeve was used. In surgical field, through the metal sleeve, the tip of a navigation probe promptly contacts to the tip of caspar pin. We measured the vertical and horizontal distances and the angular deviation in sagittal plane between the caspar pin and the navigation probe on the virtual images and evaluated accuracy of navigation system with skin fixed DRF.Results : Total 31 (males 20, females 11) patients and 48 caspar pins were included in this study. The mean horizontal distance between the caspar pin and the navigation probe displayed in navigation monitor was 0.49?±?0.71?mm. The mean vertical distance between the caspar pin and the navigation probe displayed in navigation monitor was 0.88?±?0.93?mm. And the mean angular deviation in sagittal plane between the caspar pin and the navigation probe displayed in navigation monitor was 0.59?±?0.55°.Conclusions : 3D navigation system with skin-fixed DRF in anterior cervical surgery is a simple and reliable method and it can be a helpful supplement to a spine surgeon’s judgement.
机译:目的:在颈前路手术中使用3D导航系统结合皮肤固定动态参考框架(DRF)引入简便实用的方法,并验证其准确性。方法:2012年9月至2013年5月,共有31例患者接受了检查颈椎前路手术和每个颈椎中总共插入48个卡斯帕(Caspar)牵引钉。每次操作都使用O型臂进行吗?皮肤固定DRF的导航系统。为了验证这些方法的准确性,使用了定制的金属套管。在外科手术领域中,通过金属套管,导航探针的尖端迅速接触caspar销的尖端。我们在虚拟图像上测量了caspar销和导航探针之间的垂直和水平距离以及矢状面在矢状面上的角度偏差,并评估了皮肤固定DRF的导航系统的准确性。结果:总计31(男性20,女性11) )患者和48个caspar销钉被纳入这项研究。 caspar销与导航监视器中显示的导航探针之间的平均水平距离为0.49?±?0.71?mm。 caspar销与导航监视器中显示的导航探针之间的平均垂直距离为0.88?±?0.93?mm。 caspar销与导航监视器中显示的导航探针之间在矢状面的平均角度偏差为0.59?±?0.55°。结论:前路颈椎手术中采用皮肤固定DRF的3D导航系统简单可靠方法,它可以对脊柱外科医生的判断提供有益的补充。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号