首页> 外文期刊>Clinical and diagnostic laboratory immunology >Evaluation of a New Single-Parameter Volumetric Flow Cytometer (CyFlowgreen) for Enumeration of Absolute CD4+ T Lymphocytes in Human Immunodeficiency Virus Type 1-Infected Thai Patients
【24h】

Evaluation of a New Single-Parameter Volumetric Flow Cytometer (CyFlowgreen) for Enumeration of Absolute CD4+ T Lymphocytes in Human Immunodeficiency Virus Type 1-Infected Thai Patients

机译:新型单参数体积流式细胞仪(CyFlowgreen)的评估,该计数用于枚举人类免疫缺陷病毒1型泰国患者中的绝对CD4 + T淋巴细胞。

获取原文
           

摘要

Use of the standard dual-platform flow cytometric method for determination of CD4+ T-lymphocyte counts, which needs both a flow cytometer (FCM) and hematological analyzer, would inevitably lead to increased variability. The development of new single-platform (SP) FCMs that provide direct CD4+ T-lymphocyte counts for improved assay precision and accuracy have recently attracted attention. This study evaluated one of those systems, CyFlowgreen (Partec), a single-parameter SP volumetric FCM. The performance of CyFlowgreen was compared with those of two reference standard SP microbead-based technologies of the three-color TruCOUNT tube with the FACScan FCM and a two-color FACSCount system (Becton Dickinson Biosciences). Absolute CD4+ and CD8+ T-lymphocyte counts in 200 human immunodeficiency virus type 1-seropositive blood specimens were determined. Statistical analysis for correlation and agreement were performed. A high correlation of absolute CD4 counts was shown when those obtained with CyFlowgreen were compared with those obtained with the bead-based three-color TruCOUNT system (R2 = 0.96; mean bias, ?69.1 cells/μl; 95% confidence interval [CI], ?225.7 to +87.5 cells/μl) and the FACSCount system (R2 = 0.97; mean bias, ?40.0 cells/μl; 95% CI, ?165.1 to +85.1 cells/μl). The correlation of the CD4+ T-lymphocyte counts obtained by the two bead-based systems was high (R2 = 0.98). Interestingly, CyFlowgreen yielded CD4+ T-lymphocyte counts that were 21.8 and 7.2 cells/μl lower than those obtained with the TruCOUNT and the FACSCount systems, respectively, when CD4+ T-lymphocyte counts were <250 CD4+ T-lymphocyte counts/μl range or 17.3 and 5.8 cells/μl less, respectively, when CD4+ T-lymphocyte counts were <200 cells/μl. The single-parameter CyFlowgreen?volumetric technology performed well in comparison with the performance of the standard SP bead-based FCM system. However, a multicenter comparative study is needed before this FCM machine is implemented in resource-limited settings.
机译:使用标准的双平台流式细胞术来确定CD4 + T淋巴细胞计数需要使用流式细胞仪(FCM)和血液分析仪,这不可避免地导致变异性增加。可直接提供CD4 + T淋巴细胞计数以提高检测精度和准确性的新型单平台(SP)FCM的开发近来引起了人们的关注。本研究评估了其中一个系统,CyFlow green (Partec),一种单参数SP体积FCM。将CyFlow green 的性能与带有FACScan FCM和双色FACSCount系统(Becton Dickinson Biosciences)的三色TruCOUNT管的两种基于参考标准SP微珠的技术进行了比较。测定了200例人类免疫缺陷病毒1型血清阳性样本中CD4 + 和CD8 + T淋巴细胞的绝对计数。对相关性和一致性进行统计分析。当将使用CyFlow green 获得的CD4计数与基于珠子的三色TruCOUNT系统( R 2获得的CD4计数)进行比较时,表明绝对CD4计数具有高度相关性。 = 0.96;平均偏差,?69.1细胞/μl; 95%置信区间[CI] ,? 225.7至+87.5细胞/μl)和FACSCount系统( R 2 = 0.97;平均偏差,?40.0细胞/μl; 95%CI,?165.1至+85.1细胞/μl)。通过两个基于磁珠的系统获得的CD4 + T淋巴细胞计数的相关性很高( R 2 = 0.98)。有趣的是,CyFlow green 产生的CD4 + T淋巴细胞计数分别比TruCOUNT和FACSCount系统获得的CD4 + T细胞计数分别低21.8和7.2细胞/μl。当CD4 + + T淋巴细胞计数分别为<250 CD4 + T淋巴细胞数/μl范围,或分别降低17.3和5.8细胞/μl。 > T淋巴细胞计数<200个细胞/μl。与基于标准SP珠的FCM系统的性能相比,单参数CyFlow green ?体积分析技术表现良好。但是,在此FCM机器在资源有限的环境中实施之前,需要进行多中心比较研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号