首页> 外文期刊>Clinical and diagnostic laboratory immunology >Comparison of Commercial Latex Agglutination and Sandwich Enzyme Immunoassays with a Competitive Binding Inhibition Enzyme Immunoassay for Detection of Antigenemia and Antigenuria in a Rabbit Model of Invasive Aspergillosis
【24h】

Comparison of Commercial Latex Agglutination and Sandwich Enzyme Immunoassays with a Competitive Binding Inhibition Enzyme Immunoassay for Detection of Antigenemia and Antigenuria in a Rabbit Model of Invasive Aspergillosis

机译:比较商业胶乳凝集和三明治酶免疫测定与竞争性结合抑制酶免疫测定在兔侵袭性曲霉病模型中检测抗原和尿蛋白的比较

获取原文
       

摘要

A commercial latex agglutination assay (LA) and a sandwich enzyme immunoassay (SEIA) (Sanofi Diagnostics Pasteur, Marnes-la-Coquette, France) were compared with a competitive binding inhibition assay (enzyme immunoassay [EIA]) to determine the potential uses and limitations of these antigen detection tests for the sensitive, specific, and rapid diagnosis of invasive aspergillosis (IA). Toward this end, well-characterized serum and urine specimens were obtained by using a rabbit model of IA. Serially collected serum or urine specimens were obtained daily from control rabbits or from rabbits immunosuppressed and infected systemically with Aspergillus fumigatus. By 4 days after infection, EIA, LA, and SEIA detected antigen in the sera of 93, 93, and 100% of A. fumigatus-infected rabbits, respectively, whereas antigen was detected in the urine of 93, 100, and 100% of the rabbits, respectively. False-positive results for non-A. fumigatus-infected rabbits for EIA, LA, and SEIA were as follows: for serum, 14, 11, and 23%, respectively; for urine, 14, 84, and 90%, respectively. Therefore, although the sensitivities of all three tests were similar, the specificity was generally greater for EIA than for LA or SEIA. Infection was also detected earlier by EIA, by which the serum of 53% of A. fumigatus-infected rabbits was positive as early as 1 day after infection, whereas the serum of only 27% of the rabbits tested by LA was positive. Although the serum of 92% ofA. fumigatus-infected rabbits was positive by SEIA as early as 1 day after infection, the serum of a high percentage (50%) was false positive before infection. The urine of 21% of A. fumigatus-infected rabbits was positive by EIA as early as 1 day after infection, and the urine of none of the rabbits was false positive before infection. When EIA results for urine specimens were combined with those for serum, sensitivity was improved (i.e., 67% of rabbits were positive by 1 day after infection and only one rabbit gave a false-positive result). A total of 93% of A. fumigatus-infected rabbits were positive for antigen in urine as early as 1 day after infection and the urine of 100% of the rabbits was positive by SEIA. However, before infection, 79% of A. fumigatus-infected rabbits were false positive for antigen in urine by LA and 90% were false positive for antigen in urine by SEIA. These data indicate that the EIA has the potential to be used to diagnose IA with both serum and urine specimens and to detect a greater number of infections earlier with greater specificity than the specificities achieved with the commercial tests.
机译:将商业胶乳凝集测定(LA)和夹心酶免疫测定(SEIA)(法国Sanofi Diagnostics Pasteur,Marnes-la-Coquette)与竞争性结合抑制测定(酶免疫测定[EIA])进行了比较,以确定其潜在用途和这些抗原检测测试对于侵袭性曲霉病(IA)的灵敏,特异和快速诊断的局限性。为此,使用IA兔模型获得了特征明确的血清和尿液样本。每天从对照兔或经免疫抑制并被烟曲霉全身感染的兔子获得连续收集的血清或尿液标本。感染后第4天,EIA,LA和SEIA在93、93和100%的A血清中检测到抗原。分别感染了烟熏兔,而分别在93%,100%和100%的兔子尿液中检测到抗原。非 A的假阳性结果。 EIA,LA和SEIA感染烟熏兔的情况如下:血清分别为14%,11%和23%。尿液分别为14%,84%和90%。因此,尽管所有三个测试的敏感性相似,但EIA的特异性通常比LA或SEIA的特异性更高。 EIA还较早地检测到感染,血清中53%的 A。早在感染后1天,烟熏感染的兔子就呈阳性,而LA检测的兔子中只有27%的血清呈阳性。虽然血清中有92%的A。最早在感染后1天,经SEIA感染烟气的兔子为阳性,感染前高百分比(50%)的血清为假阳性。尿液占 A的21%。最早在感染后1天,EIA感染了烟熏兔,所有兔子的尿液在感染前都没有假阳性。当将尿液样本的EIA结果与血清样本的EIA结果相结合时,灵敏度会提高(即,感染后1天,有67%的兔子呈阳性,只有一只兔子给出假阳性结果)。共有93%的 A。最早在感染后1天,被烟熏感染的兔子尿液中的抗原呈阳性,而SEIA检出100%的兔子尿液。但是,在感染前,有79%的 A。烟熏感染的兔子的LA尿液抗原假阳性,SEIA的90%尿液抗原假阳性。这些数据表明,EIA有潜力用于诊断血清和尿液样本中的IA,并能以比商业检测所获得的特异性更高的特异性更早地检测出更多的感染。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号