摘要

Objective The present study aimed to evaluate the efficacy of repetitive transcranial magnetic stimulation (rTMS) at a high frequency using a miniaturized device compared to standard rTMS and sham rTMS for the treatment of depression. Methods Fifty-four patients with depression were randomly assigned to either 15 days of miniaturized, standard, or sham rTMS. The stimulation consisted of 60 trains of 5 seconds at 10 Hz for 30 minutes. Clinical measures were assessed at baseline and on the final day of the stimulation. Results A repeated-measures analysis of variance revealed a significant main effect of time and a time by group interaction on Hamilton Rating Scale for Depression scores. There were no significant correlations between individual motor thresholds and changes of clinical outcomes. Our results revealed a significant reduction in the Hamilton Rating Scale for Depression in the miniaturized and standard groups compared to the sham group. Conclusion The antidepressant utility of miniaturized rTMS using subthreshold stimulation was comparable to that of standard stimulation.
机译:目的本研究旨在评估与标准rTMS和假rTMS相比,使用小型化设备在高频下重复经颅磁刺激(rTMS)的疗效。方法将54例抑郁症患者随机分为15天的小型,标准或假rTMS。刺激包括60串5秒的火车,在10 Hz下持续30分钟。在基线和刺激的最后一天评估临床措施。结果方差的重复测量分析显示,时间和时间对汉密尔顿抑郁量表的汉密尔顿评定量表具有显着的主要影响。个体运动阈值与临床结局变化之间无显着相关性。我们的结果显示,与假手术组相比,小型和标准组的汉密尔顿抑郁量表明显降低。结论使用亚阈值刺激进行小型化rTMS的抗抑郁作用与标准刺激作用相当。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号