Intraobserver and interobserver reliability of radial torsion angle measurements by a new and alternative method with computed tomography

机译:通过计算机断层扫描的新方法和替代方法测量径向扭转角的观察者内和观察者间可靠性

获取原文
   

获取外文期刊封面封底 >>

       

摘要

OBJECTIVE: To evaluate the intraobserver and interobserver reliability of radial torsion angle measurement using computed tomography. METHODS: Twelve pairs of cadaver radii and 116 forearms from 58 healthy volunteers were evaluated using axial computed tomography sections measured at the level of the bicipital tuberosity and the subchondral region of the radius. During digital imaging, the angle was formed by two lines, one diametrically perpendicular to the radial tubercle and the other tangential to the volar rim of the distal joint surface. Measurements were performed twice each by three observers. RESULTS: In cadaveric bones, the mean radial torsion angle was 1.48o (-6o - 9o) on the right and 1.62o (-6 o - 8o) on the left, with a mean difference between the right and left sides of 1.61o (0o - 8o). In volunteers, the mean radial torsion angle was 3.00° (-17° - 17°) on the right and 2.91° (-16°- 15°) on the left, with a mean difference between the sides of 1.58o (0o - 7o). There was no significant difference between each side. The interobserver correlation coefficient for the cadaver radii measurements was 0.88 (0.72 - 0.96) and 0.81 (0.58 - 0.93) for the right and left radius, respectively, while for the volunteers, the difference was 0.84 (0.77 - 0.90) and 0.83 (0.75 - 0.89), respectively. Intraobserver reliability was high. CONCLUSION: The described method is reproducible and applicable even when the radial tubercle has a rounded contour.
机译:目的:利用计算机体层摄影技术评估径向扭转角测量的观察者内和观察者间可靠性。方法:使用轴向计算机断层扫描切片对58名健康志愿者的十二对尸体半径和116个前臂进行评估,这些切片在二头肌结节和and骨软骨下区域的水平进行测量。在数字成像期间,该角度由两条线形成,一条线与径向结节径向垂直,另一条线与远端关节表面的掌侧缘相切。测量由三名观察员进行两次。结果:在尸体骨骼中,右侧的平均径向扭转角为1.48o(-6o-9o),左侧为1.62o(-6 o-8o),左右两侧的平均差为1.61o (0o-8o)。在志愿者中,平均径向扭转角在右侧为3.00°(-17°-17°),在左侧为2.91°(-16°-15°),两侧之间的平均差为1.58o(0o- 7o)。双方之间没有显着差异。左右半径的尸体半径测量值的观察者间相关系数分别为0.88(0.72-0.96)和0.81(0.58-0.93),而志愿者的差异为0.84(0.77-0.90)和0.83(0.75) -0.89)。观察者内部的可靠性很高。结论:所描述的方法是可重复的,即使在applicable瘤呈圆形轮廓时也可适用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号