Thromboelastography platelet mapping in healthy dogs using 1 analyzer versus 2 analyzers

机译:使用1台分析仪与2台分析仪对健康犬进行血栓弹力图血小板作图

获取原文
           

摘要

The objective of this study was to describe the results of thromboelastography platelet mapping (TEG-PM) carried out using 2 techniques in 20 healthy dogs. Maximum amplitudes (MA) generated by thrombin (MAthrombin), fibrin (MAfibrin), adenosine diphosphate (ADP) receptor activity (MAADP), and thromboxane A2 (TxA2) receptor activity (stimulated by arachidonic acid, MAAA) were recorded. Thromboelastography platelet mapping was carried out according to the manufacturer’s guidelines (2-analyzer technique) and using a variation of this method employing only 1 analyzer (1-analyzer technique) on 2 separate blood samples obtained from each dog. Mean [± standard deviation (SD)] MA values for the 1-analyzer/2-analyzer techniques were: MAthrombin = 51.9 mm (± 7.1)/52.5 mm (± 8.0); MAfibrin = 20.7 mm (± 21.8)/23.0 mm (± 26.1); MAADP = 44.5 mm (± 15.6)/45.6 mm (± 17.0); and MAAA = 45.7 mm (± 11.6)/45.0 mm (± 15.4). Mean (± SD) percentage aggregation due to ADP receptor activity was 70.4% (± 32.8)/67.6% (± 33.7). Mean percentage aggregation due to TxA2 receptor activity was 77.3% (± 31.6)/78.1% (± 50.2). Results of TEG-PM were not significantly different for the 1-analyzer and 2-analyzer methods. High correlation was found between the 2 methods for MAfibrin [concordance correlation coefficient (r) = 0.930]; moderate correlation was found for MAthrombin (r = 0.70) and MAADP (r = 0.57); correlation between the 2 methods for MAAA was lower (r = 0.32). Thromboelastography platelet mapping (TEG-PM) should be further investigated to determine if it is a suitable method for measuring platelet dysfunction in dogs with thrombopathy.
机译:这项研究的目的是描述使用20种健康狗中的2种技术进行的血栓弹力描记术血小板作图(TEG-PM)的结果。记录由凝血酶(MAthrombin),纤维蛋白(MAfibrin),二磷酸腺苷(ADP)受体活性(MAADP)和血栓烷A2(TxA2)受体活性(由花生四烯酸,MAAA刺激)产生的最大振幅(MA)。血栓弹力图血小板作图是根据制造商的指导原则(2-分析仪技术)进行的,并且使用了该方法的一种变体,仅对每只狗的2个独立的血液样本使用了一个分析仪(1-分析仪技术)。 1-分析仪/ 2分析仪技术的平均[±标准偏差(SD)] MA值为:凝血酶= 51.9毫米(±7.1)/52.5毫米(±8.0); MAfibrin = 20.7毫米(±21.8)/23.0毫米(±26.1); MAADP = 44.5毫米(±15.6)/45.6毫米(±17.0); MAAA = 45.7毫米(±11.6)/45.0毫米(±15.4)。由于ADP受体活性而导致的平均(±SD)聚集百分比为70.4%(±32.8)/67.6%(±33.7)。由于TxA2受体活性而导致的平均聚集百分比为77.3%(±31.6)/78.1%(±50.2)。 1-分析仪和2-分析仪方法的TEG-PM结果没有显着差异。在两种MAfibrin方法之间发现高度相关[一致性相关系数(r)= 0.930]; MAthrombin(r = 0.70)和MAADP(r = 0.57)有中等相关性;两种方法对MAAA的相关性较低(r = 0.32)。应进一步研究血栓弹力图血小板作图(TEG-PM),以确定它是否是测量患有血栓病的狗的血小板功能障碍的合适方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号