首页> 外文期刊>Case Reports in Orthopedics >Fracture of Ceramic Liner and Head in a Total Hip Arthroplasty with a Sandwich Type Cup
【24h】

Fracture of Ceramic Liner and Head in a Total Hip Arthroplasty with a Sandwich Type Cup

机译:夹层杯全髋关节置换术中陶瓷内胆和头部的骨折

获取原文
           

摘要

Due to its advantages, ceramic-on-ceramic bearings have been widely used in young patients for almost 30 years. Long-term survivorship, low wear, and low biological reactivity to particles are some of its characteristics. Even though this material has had a lot of improvements, the risk of fracture is one of the concerns. There have been reports of fracture of ceramic in the acetabular liner and head but no fractures of both in the same patient. We report a case of a fracture in a sandwich type acetabular liner and the ceramic head in a patient involving ankylosing spondylitis. It occurred three years after the operation and with no history of direct trauma. We decided to change the bearing surfaces to metal polyethylene without removing the metal back. The patient is satisfied by the clinical results after a 5-year followup.
机译:由于其优点,陶瓷陶瓷轴承已在年轻患者中广泛使用了近30年。长期生存,低磨损和对颗粒的低生物反应性是其某些特征。即使这种材料已经有了很大的改进,但破裂的风险仍然是人们关注的问题之一。有报告说髋臼内衬和头部的陶瓷破裂,但同一位患者均没有骨折。我们报道了一名涉及强直性脊柱炎的患者的夹层式髋臼内衬和陶瓷头骨折。它发生在手术后三年,没有直接的创伤史。我们决定将轴承表面更改为金属聚乙烯,而无需去除金属后盖。经过5年的随访,患者对临床结果感到满意。