Background: 18F-fluorodeoxyglucose (FDG) positron emission tomography computed tomography (PET/CT) provides information about metabolic and morphologic status of malignancies. Tumor size and standardized uptake value (SUV) measurements are crucial for cancer treatment monitoring. Aims: The purpose of our study was to assess the variability of these measurements performed by observers evaluating lung tumors. Study Design: Retrospective cross-sectional study. Methods: FDG PET/CT images of 97 patients with pulmonary tumors were independently evaluated by two experienced nuclear medicine physicians. Primary tumor size (UDCT), maximum SUV (SUVmax), mean SUV (SUVmean) and maximum SUV normalized to liver mean SUV (SUVnliv max) were measured by each observer at two different times with an interval of at least 2 weeks. Interobserver and intraobserver variabilities of measurements were evaluated through statistical methods. Results: Size of the lesions varied from 0.81 to 13.6 cm (mean 4.29±2.24 cm). Very good agreement was shown with correlation, Bland-Altman and regression analysis for all measured PET/CT parameters. In the interobserver and intraobserver variability analysis, the Pearson correlation coefficients were greater than 0.96 and 0.98, respectively. Conclusion: Semi-quantitative measurements of pulmonary tumors were highly reproducible when determined by experienced physicians with clinically available software for routine FDG PET/CT evaluation. Consistency may be improved if the same observer performs serial measurements for any one patient.
机译:背景:18F-氟脱氧葡萄糖(FDG)正电子发射断层扫描计算机断层扫描(PET / CT)提供有关恶性肿瘤代谢和形态学状态的信息。肿瘤大小和标准化摄取值(SUV)测量对于癌症治疗监测至关重要。目的:我们研究的目的是评估观察者评估肺肿瘤的测量结果的变异性。研究设计:回顾性横断面研究。方法:由两名经验丰富的核医学医师对97例肺部肿瘤的FDG PET / CT图像进行独立评估。每个观察者在两个不同的时间间隔至少2周对原发肿瘤大小(UDCT),最大SUV(SUVmax),平均SUV(SUVmean)和标准化为肝平均SUV(SUVnliv max)的最大SUV进行测量。观察者之间和观察者内部的测量差异通过统计学方法进行评估。结果:病变的大小从0.81到13.6 cm不等(平均4.29±2.24 cm)。对所有测得的PET / CT参数的相关性,Bland-Altman和回归分析显示出非常好的一致性。在观察者间和观察者内变异性分析中,Pearson相关系数分别大于0.96和0.98。结论:由经验丰富的医师使用可用于常规FDG PET / CT评估的临床可用软件确定时,肺肿瘤的半定量测量具有高度可重复性。如果同一位观察者对任何一名患者执行串行测量,则一致性可能会得到改善。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号