首页> 外文期刊>Acta Radiologica >Interobserver variability among measurements of the maximum and mean standardized uptake values on (18)F-FDG PET/CT and measurements of tumor size on diagnostic CT in patients with pulmonary tumors.
【24h】

Interobserver variability among measurements of the maximum and mean standardized uptake values on (18)F-FDG PET/CT and measurements of tumor size on diagnostic CT in patients with pulmonary tumors.

机译:肺部肿瘤患者在(18)F-FDG PET / CT的最大和平均标准化摄取值的测量值与诊断性CT的肿瘤大小测量值之间的观察者间差异。

获取原文
获取原文并翻译 | 示例
       

摘要

BACKGROUND: (18)F-fluoro-2-deoxyglucose positron emission tomography ((18)F-FDG PET) imaging has been shown to be an accurate method for diagnosing pulmonary lesions, and the standardized uptake value (SUV) has been shown to be useful in differentiating benign from malignant lesions. PURPOSE: To survey the interobserver variability of SUV(max) and SUV(mean) measurements on (18)F-FDG PET/CT scans and compare them with tumor size measurements on diagnostic CT scans in the same group of patients with focal pulmonary lesions. MATERIAL AND METHODS: Forty-three pulmonary nodules were measured on both (18)F-FDG PET/CT and diagnostic chest CT examinations. Four independent readers measured the SUV(max) and SUV(mean) of the (18)F-FDG PET images, and the unidimensional nodule size of the diagnostic CT scans (UD(CT)) in all nodules. The region of interest (ROI) for the SUV measurements was drawn manually around each tumor on all consecutive slices that contained the nodule. The interobserver reliability and variability, represented by the intraclass correlation coefficient (ICC) and coefficient of variation (COV), respectively, were compared among the three parameters. The correlation between the SUV(max) and SUV(mean) was also analyzed. RESULTS: There was 100% agreement in the SUV(max) measurements among the 4 readers in the 43 pulmonary tumors. The ICCs for the SUV(max), SUV(mean), and UD(CT) by the four readers were 1.00, 0.97, and 0.97, respectively. The root-mean-square values of the COVs for the SUV(max), SUV(mean), and UD(CT) by the four readers were 0%, 13.56%, and 11.03%, respectively. There was a high correlation observed between the SUV(max) and SUV(mean) (Pearson's r=0.958; P <0.01). CONCLUSION: This study has shown that the SUV(max) of lung nodules can be calculated without any interobserver variation. These findings indicate that SUV(max) is a more valuable parameter than the SUV(mean) or UD(CT) for the evaluation of therapeutic effects of chemotherapy or radiation therapy on serial studies.
机译:背景:(18)F-氟-2-脱氧葡萄糖正电子发射断层扫描((18)F-FDG PET)成像已被证明是诊断肺部病变的准确方法,并且标准化摄取值(SUV)已被证明可可用于区分良性和恶性病变。目的:调查(18)F-FDG PET / CT扫描中SUV(max)和SUV(平均值)测量值在观察者之间的变异性,并将其与同一组局灶性肺部病变患者的CT扫描结果与肿瘤大小测量值进行比较。材料与方法:在(18)F-FDG PET / CT和胸部CT诊断检查中测量了43个肺结节。四个独立的读取器测量了(18)F-FDG PET图像的SUV(max)和SUV(mean),以及所有结节中诊断CT扫描(UD(CT))的一维结节大小。在包含结节的所有连续切片上,在每个肿瘤周围手动绘制用于SUV测量的目标区域(ROI)。在三个参数中,比较了观察者间的可靠性和变异性,分别由组内相关系数(ICC)和变异系数(COV)表示。还分析了SUV(最大值)和SUV(平均值)之间的相关性。结果:在43例肺部肿瘤的4名读者中,SUV(max)的测量结果具有100%的一致性。四个读者的SUV(max),SUV(mean)和UD(CT)的ICC分别为1.00、0.97和0.97。四个读取器的SUV(max),SUV(mean)和UD(CT)的COV的均方根值分别为0%,13.56%和11.03%。 SUV(最大值)和SUV(平均值)之间存在高度相关性(Pearson r = 0.958; P <0.01)。结论:这项研究表明,肺结节的SUV(最大值)可以在观察者之间没有任何变化的情况下进行计算。这些发现表明,SUV(max)比SUV(mean)或UD(CT)在系列研究中评估化学疗法或放射疗法的治疗效果时,是更有价值的参数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号