首页> 外文期刊>Cancer Management and Research >Comprehensive analysis of clinical utility of three-dimensional ultrasound for benign and malignant breast masses
【24h】

Comprehensive analysis of clinical utility of three-dimensional ultrasound for benign and malignant breast masses

机译:三维超声对乳腺良恶性肿块临床实用性的综合分析

获取原文
           

摘要

Background: Three-dimensional (3-D) ultrasound is commonly used for screening breast cancer; however, the diagnostic accuracy of this method is unknown. Here, we performed a systematic search on the literature to assess the clinical utility of 3-D ultrasound in benign and malignant breast masses. Materials and methods: We conducted searches in several online databases covering all publications prior to August 15, 2017. The bivariate random effects model was used to assess the overall sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and summary area under receiver operating curve (AUC) with their corresponding 95% CI. Results: The overall sensitivity of 3-D ultrasound for diagnosing benign and malignant breast masses was 89% (95% CI, 83%–93%) and the specificity was 88% (95% CI, 83%–92%) with high heterogeneity ( I2 =81.9; 95% CI, 74.4–89.3, P 0.001). Other parameters used to assess efficacy included PLR (5.57; 95% CI, 3.73–8.31), NLR (0.18; 95% CI, 0.11–0.28), and DOR (31.33; 95% CI, 15.19–64.61). The use of a Fagan diagram with a pretest probability of 20% yields a post-test probability of 65% with a PLR of 7. True post-test probability was calculated at 3%, with an NLR of 0.13. The summary receiver operating characteristic curve was 0.94 (95% CI, 0.92–0.96), with no evidence of publication bias. Conclusion: Three-dimensional ultrasound offers high sensitivity and specificity, with a high AUC, indicating a strong diagnostic value for detecting benign and malignant breast masses. Three-dimensional ultrasound may therefore represent an excellent option for secondary analysis of unclear breast lesions.
机译:背景:三维(3-D)超声通常用于筛查乳腺癌。但是,这种方法的诊断准确性尚不清楚。在这里,我们对文献进行了系统的搜索,以评估3-D超声在乳腺良性和恶性肿块中的临床效用。材料和方法:我们在2017年8月15日之前在覆盖所有出版物的几个在线数据库中进行了搜索。使用双变量随机效应模型评估整体敏感性,特异性,阳性似然比(PLR),阴性似然比(NLR),诊断比值比(DOR),以及接收器工作曲线(AUC)下的汇总区域及其相应的95%CI。结果:3D超声诊断乳腺良恶性的总体敏感性为89%(95%CI,83%–93%),特异性为88%(95%CI,83%–92%),高异质性(I2 = 81.9; 95%CI,74.4–89.3,P <0.001)。用于评估功效的其他参数包括PLR(5.57; 95%CI,3.73–8.31),NLR(0.18; 95%CI,0.11-0.28)和DOR(31.33; 95%CI,15.19-64.61)。使用Fagan图(具有20%的预测试概率)会产生65%的后测试概率,PLR为7。真实的后测试概率为3%,NLR为0.13。汇总的接收者工作特征曲线为0.94(95%CI,0.92-0.96),没有证据显示发表偏倚。结论:三维超声检查具有较高的灵敏度和特异性,AUC较高,对乳腺良恶性肿块的诊断具有很强的诊断价值。因此,三维超声可能是对不清楚的乳房病变进行二级分析的极佳选择。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号