Diagnostic performance and inter-observer concordance in lesion detection with the automated breast volume scanner (ABVS)

机译:自动乳房体积扫描仪(ABVS)在病变检测中的诊断性能和观察者之间的一致性

获取原文
           

摘要

Background Automated whole breast ultrasound scanners of the latest generation have reached a level of comfortable application and high quality volume acquisition. Nevertheless, there is a lack of data concerning this technology. We investigated the diagnostic performance and inter-observer concordance of the Automated Breast Volume Scanner (ABVS) ACUSON S2000? and questioned its implications in breast cancer diagnostics. Methods We collected 100 volume data sets and created a database containing 52 scans with no detectable lesions in conventional ultrasound (BI-RADS?-US 1), 30 scans with benign lesions (BI-RADS?-US 2) and 18 scans with breast cancer (BI-RADS?-US 5). Two independent examiners evaluated the ABVS data on a separate workstation without any prior knowledge of the patients’ histories. Results The inter-rater reliability reached fair agreement (κ=0.36; 95% confidence interval (CI): 0.19-0.53). With respect to the true category, the conditional inter-rater validity coefficient was κ=0.18 (95% CI: 0.00-0.26) for the benign cases and κ=0.80 (95% CI: 0.61-1.00) for the malignant cases. Combining the assessments of examiner 1 and examiner 2, the diagnostic accuracy (AC), sensitivity (SE) and specificity (SP) for the experimental ABVS were AC = 79.0% (95% CI: 67.3-86.1), SE = 83.3% (95% CI: 57.7-95.6) and SP = 78.1% (% CI: 67.3-86.1), respectively. However, after the ABVS examination, there were a high number of requests for second-look ultrasounds in up to 48.8% of the healthy women due to assumed suspicious findings in the volume data. In an exploratory analysis, we estimated that an ABVS examination in addition to mammography alone could detect a relevant number of previously occult breast cancers (about 1 cancer in 300 screened and otherwise healthy women). Conclusions The ABVS is a reliable imaging method for the evaluation of the breast with high sensitivity and a fair inter-observer concordance. However, we have to overcome the problem of the high number of false-positive results. Therefore, further prospective studies in larger collectives are necessary to define standard procedures in image acquisition and interpretation. Nevertheless, we consider the ABVS as being suitable for integration into breast diagnostics as a beneficial and reliable imaging method.
机译:背景技术最新一代的自动全乳超声扫描仪已经达到舒适的应用水平和高质量的采集量。然而,缺乏有关该技术的数据。我们调查了自动乳房体积扫描仪(ABVS)ACUSON S2000的诊断性能和观察者之间的一致性。并质疑其对乳腺癌诊断的意义。方法我们收集了100份体积数据集,并创建了一个数据库,其中包含52例常规超声检查(BI-RADS?-US 1)中没有可检测到的病变,30例良性病变(BI-RADS?-US 2)中的扫描和18例乳腺扫描癌症(BI-RADS?-US 5)。两名独立的检查员在没有事先了解患者病史的情况下,在单独的工作站上评估了ABVS数据。结果评分者之间的信度达到合理的一致性(κ= 0.36; 95%置信区间(CI):0.19-0.53)。对于真实类别,良性病例的条件评价者间效度系数为κ= 0.18(95%CI:0.00-0.26),恶性病例为κ= 0.80(95%CI:0.61-1.00)。结合检查者1和检查者2的评估,实验性ABVS的诊断准确性(AC),敏感性(SE)和特异性(SP)为AC = 79.0%(95%CI:67.3-86.1),SE = 83.3%( 95%CI:57.7-95.6)和SP = 78.1%(%CI:67.3-86.1)。但是,在ABVS检查之后,由于体数据中的可疑发现,多达48.8%的健康女性对第二次超声检查的要求很高。在一项探索性分析中,我们估计,除乳房X光检查外,ABVS检查还可以检测到一定数量的先前隐匿性乳腺癌(300名接受过筛查的健康女性中约有1例癌症)。结论ABVS是一种评估乳腺的可靠成像方法,具有高灵敏度和观察者之间的一致性。但是,我们必须克服大量假阳性结果的问题。因此,有必要在较大的集体中进行进一步的前瞻性研究,以定义图像采集和解释的标准程序。尽管如此,我们认为ABVS适合作为一种有益且可靠的影像学方法整合到乳房诊断中。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号