首页> 外文期刊>Bali Medical Journal >The comparison of ion exchange-high performance liquid chromatography (IE-HPLC) and capillary electrophoresis (CE) for HbA1C measurement
【24h】

The comparison of ion exchange-high performance liquid chromatography (IE-HPLC) and capillary electrophoresis (CE) for HbA1C measurement

机译:离子交换高效液相色谱(IE-HPLC)和毛细管电泳(CE)用于HbA1C测量的比较

获取原文

摘要

Background: HbA1c is a glycosylated hemoglobin that routinely performed in patient with Diabetes Mellitus. There are several methods for HbA1c measurement. One of them are based on the molecular charge such as High Performance Liquid Chromatography(HPLC) and Capillary Electrophoresis (CE). Each method has its own advantages and disadvantages. Thus, the selection of HbA1c measurement method is an important thing. This study was aimed to compare HbA1c measurement with HPLC and CE method. Methods: HbA1c measurement was done by HPLC and CE methods in 110 patient samples which have data of average blood glucose level during three months. We investigate the correlation of HbA1c results with average blood glucose level during three months,precision, methods comparison and interference including Hb varian. This study was conducted in Central Laboratory of dr. Saiful Anwar? Hospital during March–August 2018. Correlation analysis were done by Pearson analysis while precision test and methods comparison were done by Bland Altman Plot and Passing-bablok Regression analysis. Results: There were correlation between estimated Average Glucose from HbA1c (eAGHbA1c) calculation with average blood glucose level during 3 months in both methods.From precision test we found intra-assay coefficient of variation in normal level (HbA1c ±5%) by HPLC vs CE was 1,7% vs 0.63% and in high level (HbA1c ±11%) was 0,59% vs 0,61% and inter-assay coefficient of variation by HPLC vs CE was 2,47% vs 2,17%. Method comparation results showed strong correlation on both method. The results of HbA1c in group without Hb variant by CE method was slightly lower than HPLC. In Hb variant group, CE method was slightly higher than HPLC, but it was not significant for HbA1c interpretation. Conclusion: HbA1c measurement by HPLC and CE method are comparable and there is no significant difference in the results obtained.
机译:背景:HbA1c是糖化血红蛋白,通常在糖尿病患者中进行。 HbA1c测量有几种方法。其中之一是基于分子电荷的,例如高效液相色谱(HPLC)和毛细管电泳(CE)。每种方法都有其自身的优点和缺点。因此,HbAlc测量方法的选择是重要的。这项研究旨在比较HPLC和CE方法对HbA1c的测量。方法:通过HPLC和CE方法对110例患者样本进行HbA1c测定,这些样本具有三个月的平均血糖水平。我们调查了三个月内HbA1c结果与平均血糖水平的相关性,精密度,方法比较和包括Hb变异的干扰。这项研究是在博士中心实验室进行的。 Saiful Anwar?医院于2018年3月至8月期间。相关分析通过Pearson分析进行,而精密度测试和方法比较通过Bland Altman图解和Passing-bablok回归分析进行。结果:两种方法的HbA1c计算得出的平均血糖估计值(eAGHbA1c)与3个月内的平均血糖水平之间存在相关性。从精密度测试中,我们发现HPLC内分析测定内正常水平的变异系数(HbA1c±5%)与CE为1.7%对0.63%,高水平(HbA1c±11%)为0.59%对0.61%,HPLC对CE的批间变异系数为2,47%对2,17% 。方法比较结果显示两种方法之间具有很强的相关性。 CE法检测无Hb变异的组中HbA1c结果略低于HPLC。在Hb变异组中,CE方法略高于HPLC,但对HbA1c的解释并不重要。结论:HPLC和CE法检测HbA1c具有可比性,结果无明显差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号