首页> 外文期刊>Dental materials >Low temperature degradation and reliability of one-piece ceramic oral implants with a porous surface
【24h】

Low temperature degradation and reliability of one-piece ceramic oral implants with a porous surface

机译:具有多孔表面的一体式陶瓷口腔植入物的低温降解和可靠性

获取原文
获取原文并翻译 | 示例
       

摘要

Low temperature degradation of zirconia (3Y-TZP) oral implants and its effect on fatigue reliability is poorly documented. Objective. The aim of this investigation was to follow the aging process occurring at the surface of implants exhibiting a porous coating and to assess its influence on their mechanical (fatigue) properties. Methods. Tetragonal to monoclinic transformation (t-m) was evaluated during accelerated aging tests up to 100 h in autoclave (134 ℃, 2 bars) by X-ray diffraction (XRD) and focused ion beam (FIB). A series of implants were steam-aged for 20 h before fatigue testing. Such temperature-time conditions would correspond roughly to 40 years in vivo. The aged specimens and a non-aged control group were step-stress fatigued until failure or survival. Results. The evolution of XRD surface monoclinic content was slow, i.e. 16% and 35% for 20 and 100 h respectively. However, FIB revealed a significant transformation, initiated at the interface between the porous layer and the bulk, preferentially growing towards the bulk. FIB is therefore better indicated than XRD to follow aging in such implants. Higher average fatigue strength (aged 1235 N versus non-aged 826 N) and reliability levels were observed for the 20 h aged group. Significance. After aging for durations compatible with clinical use, 3Y-TZP with porous surface presented higher fatigue performance. This is in contrast to previous studies where loss of strength due to aging was often reported. Generalizations must therefore be avoided when considering aging of zirconia dental products and every new material/process combination should be tested before drawing conclusions.
机译:氧化锆(3Y-TZP)口腔植入物的低温降解及其对疲劳可靠性的影响文献很少。目的。这项研究的目的是跟踪出现在具有多孔涂层的植入物表面的老化过程,并评估其对机械(疲劳)性能的影响。方法。通过X射线衍射(XRD)和聚焦离子束(FIB)在高压釜(134℃,2 bar)中进行了长达100 h的加速老化测试,评估了四方晶向单斜晶的转变(t-m)。在疲劳测试之前,将一系列植入物进行蒸汽老化20小时。这样的温度时间条件将大致相当于体内40年。老化的标本和未老化的对照组逐步疲劳直至衰竭或存活。结果。 XRD表面单斜晶含量的变化缓慢,即20和100 h分别为16%和35%。然而,FIB显示出显着的转变,该转变始于多孔层与主体之间的界面,优先向主体生长。因此,与XRD相比,FIB更好地指示了此类植入物中的老化。在20 h时效组中,观察到更高的平均疲劳强度(1235 N时相比826 N)。意义。老化达到与临床使用相适应的持续时间后,具有多孔表面的3Y-TZP表现出更高的疲劳性能。这与以前的研究相反,以前的研究经常报道由于老化而导致强度下降。因此,在考虑氧化锆牙科产品的时效时,必须避免归纳,在得出结论之前,应对每种新材料/工艺组合进行测试。

著录项

  • 来源
    《Dental materials》 |2013年第4期|389-397|共9页
  • 作者单位

    INSA-Lyon, UMR CNRS 5510 (MATEIS), 7 avenue Jean Capelle, 69621 Villeurbanne Cedex, France,University Lyon 1, Faculty of Odontology, Department of Biomaterials, 11, Rue Guillaume Paradin, 69372 Lyon cedex 08, France;

    INSA-Lyon, UMR CNRS 5510 (MATEIS), 7 avenue Jean Capelle, 69621 Villeurbanne Cedex, France;

    INSA-Lyon, UMR CNRS 5510 (MATEIS), 7 avenue Jean Capelle, 69621 Villeurbanne Cedex, France;

    Department o/Prosthodontics, Dental School, University of Freiburg, 79106 Freiburg, Germany;

    New York University College of Dentistry, 345 East 24th Street Room 812, New Yorfe, USA;

    New York University College of Dentistry, 345 East 24th Street Room 812, New Yorfe, USA,University of Turku, Department of Biomaterials Science, Lemminkaeisenkatu 2, 20520 Turku, Finland;

    School of Dentistry/Federal University o/Minas Gerais, UFMG/FO, Brazil;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Dental implants; Zirconia; Transformation; Reliability; Fatigue; Surface modification; Cracks; Focused ion beam;

    机译:牙种植体;氧化锆转型;可靠性;疲劳;表面改性;裂缝;聚焦离子束;
  • 入库时间 2022-08-18 03:47:02