首页> 外文期刊>Journal of chemical health & safety >Microscopic analysis of glovebox glove failures and breaches
【24h】

Microscopic analysis of glovebox glove failures and breaches

机译:手套箱手套故障和断裂的微观分析

获取原文
获取原文并翻译 | 示例
           

摘要

Programmatic operations at the Los Alamos National Laboratory Plutonium Facility (TA-55) involve working with plutonium and other highly toxic, alpha-emitting materials. The spread of radiological contamination on surfaces, airborne contamination, and excursions of contaminants into the operator's breathing zone are prevented using gloveboxes. The TA-55 Glovebox Safety Program augments this passive safety feature. A key element of this program is to perform microscopic analyses of glovebox glove failures and breaches when their causes are unknown. Initial examinations provide little information about the causes of failures and breaches. This has prompted the development of an instrument that permits cross-sections of glove perforations to be studied. This paper discusses the methodology used to perform microscopic analysis of failures and breaches. It presents three case studies in which microscopic analyses have helped to determine the causes of the glove openings.
机译:洛斯阿拉莫斯国家实验室P设施(TA-55)的程序性操作涉及使用p和其他高毒性的发射α的材料。使用手套箱可以防止放射性污染物在表面上的扩散,空气传播的污染物以及污染物进入操作员呼吸区域的移动。 TA-55手套箱安全计划增强了这种被动安全功能。该程序的关键要素是在未知原因的情况下对手套箱的手套故障和破裂进行微观分析。初步检查几乎没有提供有关失败和破坏原因的信息。这推动了仪器的开发,该仪器允许研究手套穿孔的横截面。本文讨论了用于对故障和违规进行微观分析的方法。它提供了三个案例研究,其中微观分析有助于确定手套开口的原因。