首页> 外文期刊>Biomedical Chromatography >Development and validation of a reliable high-performance liquid chromatographic method for determination of nodakenin in rat plasma and its application to pharmacokinetic study
【24h】

Development and validation of a reliable high-performance liquid chromatographic method for determination of nodakenin in rat plasma and its application to pharmacokinetic study

机译:一种可靠的高效液相色谱法测定大鼠血浆中Nodakenin的方法开发与验证及其在药代动力学研究中的应用

获取原文
获取原文并翻译 | 示例
       

摘要

AbstractA simple and reliable high-performance liquid chromatographic (HPLC) method has been developed for the determination of nodakenin in rat plasma. The concentration of nodakenin was determined in plasma samples after deproteinization with methanol using hesperidin as internal standard. HPLC analysis was performed on a Diamonsil C18 analytical column using acetonitrile–water (25:75, v/v) as the mobile phase and a UV detection at 330?nm. This method was validated in terms of recovery, linearity, accuracy and precision (intra- and inter-day variation). The extraction recoveries were 91.3 ± 10, 87.8 ± 4.8 and 92.6 ± 5.1 at concentrations of 0.500, 5.00 and 40.0?μg/mL, respectively. The standard curve for nodakenin was linear (r2 ≥ 0.99) over the concentration range 0.250–50.0?μg/mL with a lower limit of quantification of 0.250?μg/mL. The intra- and inter-day precision (relative standard deviation, RSD) values were not higher than 12% and the accuracy (relative error, RE) was within ±5.8% at three quality control levels. The validated method was successfully applied for the evaluation of the pharmacokinetics of nodakenin in rats after oral administration of Rhizoma et Radix Notopterygii decoction and nodakenin solution. Copyright ? 2010 John Wiley & Sons, Ltd.
机译:摘要建立了一种简单可靠的高效液相色谱(HPLC)方法测定大鼠血浆中的Nodakenin。使用橙皮苷作为内标物,在用甲醇脱蛋白后,测定血浆样品中Nodakenin的浓度。 HPLC分析在Diamonsil C 18 分析柱上进行,使用乙腈-水(25:75,v / v)作为流动相,并在330?nm处进行UV检测。该方法在回收率,线性,准确性和精密度(日内和日间变化)方面得到了验证。浓度为0.500、5.00和40.0μg/ mL时,提取回收率分别为91.3±10、87.8±4.8和92.6±5.1。浓度在0.250–50.0?μg/ mL范围内的Nodakenin的标准曲线是线性的(r 2 ≥0.99),定量下限为0.250?μg/ mL。在三个质量控制级别上,日内和日间精度(相对标准偏差,RSD)值均不高于12%,精度(相对误差,RE)在±5.8%以内。经验证的方法已成功地应用于大鼠根部和opter活汤加诺达克宁溶液口服给药后,诺达克宁在大鼠体内的药代动力学评估。版权? 2010 John Wiley&Sons,Ltd.

著录项

  • 来源
    《Biomedical Chromatography》 |2011年第10期|1076-1080|共5页
  • 作者

    Zhigang Liu; Famei Li;

  • 作者单位

    Department of Analytical Chemistry Shenyang Pharmaceutical University 103 Wenhua Road Shenyang 110016 People's Republic of China;

    Department of Biological and Environmental Engineering Guiyang University Guiyang 550005 People's Republic of China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    nodakenin; HPLC; rat plasma; pharmacokinetics;

    机译:Nodakenin;HPLC;大鼠血浆;药代动力学;
  • 入库时间 2022-08-17 14:10:09

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号