首页> 外文期刊>Behavior Research Methods >A convenient and accurate parallel Input/Output USB device for E-Prime
【24h】

A convenient and accurate parallel Input/Output USB device for E-Prime

机译:适用于E-Prime的便捷,准确的并行输入/输出USB设备

获取原文
获取原文并翻译 | 示例

摘要

Psychological and neurophysiological experiments require the accurate control of timing and synchrony for Input/Output signals. For instance, a typical Event-Related Potential (ERP) study requires an extremely accurate synchronization of stimulus delivery with recordings. This is typically done via computer software such as E-Prime, and fast communications are typically assured by the Parallel Port (PP). However, the PP is an old and disappearing technology that, for example, is no longer available on portable computers. Here we propose a convenient USB device enabling parallel I/O capabilities. We tested this device against the PP on both a desktop and a laptop machine in different stress tests. Our data demonstrate the accuracy of our system, which suggests that it may be a good substitute for the PP with E-Prime.
机译:心理和神经生理学实验要求对输入/输出信号的时间和同步进行精确控制。例如,典型的事件相关电位(ERP)研究要求刺激传递与录音的极其精确的同步。这通常通过计算机软件(例如E-Prime)完成,并且通常通过并行端口(PP)确保快速通信。但是,PP是一种古老且正在消失的技术,例如,在便携式计算机上不再可用。在这里,我们提出了一种方便的USB设备,该设备支持并行I / O功能。在不同的压力测试中,我们针对台式机和笔记本电脑上的PP对该设备进行了测试。我们的数据证明了我们系统的准确性,这表明它可以很好地替代带有E-Prime的PP。