Energy Dispersive X-ray Fluorescence (EDXRF) was compared to Inductively Coupled Plasma Mass Spectrometer (ICP-MS) for the measurements of elements (Mg, Al, Si, S, Cl, K, Ca, Ti, V, Cr, Fe, Co, Ni, Mn, Cu, Zn, As, Br, Sr, Pb, Mo, Cd, Sn and Sb) in particulate matter (PMin) collected on Teflon and two types of quartz filters at different sites. Two different methods of EDXRF analysis, linear calibration and standardless analysis, were studied. For the linear calibration, Pb, Mn, Fe, Cu, Ti and Zn were found to be site and filter type independent whereas Ca was only site independent. The site effect was evidenced for K, As, Ni, and V for quartz filter. The standardless EDXRF analysis showed better results than linear calibrations except for As, Co and V for Teflon filters and Cr and V for quartz filters. The measurement uncertainty of standardless EDXRF analysis was estimated by establishing a model equation. The measurement uncertainty estimated with this model equation was confirmed by field experiments provided that elemental masses exceeded observed thresholds. It was found that standardless EDXRF analysis is able to quantify most of the elements studied, particularly on Teflon filters rather than quartz filters. The standardless EDXRF analysis complies with the data quality objectives (DQO) of European Directives to measure Pb in PM_(10) for three types of filters, even at concentrations lower than limit values (LV). The detection limits (MDL) of standardless EDXRF analysis for measuring As and Cd were found to be insufficient to meet the legislative requirements. The MDL of Ni was sufficiently low for measurements; however, measurement uncertainties remained higher than the DQO at the lower concentrations than LV.
机译:将能量色散X射线荧光(EDXRF)与电感耦合等离子体质谱仪(ICP-MS)进行了比较,以测量元素(Mg,Al,Si,S,Cl,K,Ca,Ti,V,Cr,Fe,聚四氟乙烯和两种类型的石英过滤器在不同位置收集的颗粒物(PMin)中的Co,Ni,Mn,Cu,Zn,As,Br,Sr,Pb,Mo,Cd,Sn和Sb)研究了EDXRF分析的两种不同方法,即线性校准和无标分析。对于线性校准,发现Pb,Mn,Fe,Cu,Ti和Zn与位置和过滤器类型无关,而Ca仅与位置无关。石英滤光片的K,As,Ni和V的位置效应得到了证明。除铁氟龙滤光片的As,Co和V以及石英滤光片的Cr和V外,无标EDXRF分析显示出比线性校准更好的结果。通过建立模型方程来估算无标准EDXRF分析的测量不确定度。如果元素质量超过观察到的阈值,则通过现场实验证实了使用该模型方程估算的测量不确定性。结果发现,无标准EDXRF分析能够量化研究的大多数元素,尤其是在特氟龙滤光片而非石英滤光片上。无标准EDXRF分析符合欧洲指令的数据质量目标(DQO),即使在浓度低于限值(LV)的情况下,也可以测量三种类型的过滤器在PM_(10)中的Pb。发现用于测量砷和镉的无标准EDXRF分析的检出限(MDL)不足以满足法律要求。 Ni的MDL值足够低,无法测量。但是,在低于LV的浓度下,测量不确定度仍高于DQO。

著录项

  • 来源
    《Atmospheric environment》 |2012年第7期|p.568-582|共15页
  • 作者单位

    European Commission, joint Research Centre, Institute for Environment and Sustainability, Via Enrico Fermi 2749, 21027 Ispra (VA), Italy;

    European Commission, joint Research Centre, Institute for Environment and Sustainability, Via Enrico Fermi 2749, 21027 Ispra (VA), Italy;

    European Commission, joint Research Centre, Institute for Environment and Sustainability, Via Enrico Fermi 2749, 21027 Ispra (VA), Italy;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    heavy metals; EDXRF; uncertainty; standardless analysis; PM_(10); ICP-MS;