首页> 外文期刊>IEEE Transactions on Applied Superconductivity >Electrical testing of large scale IR&D dummy coil for TPX magnet insulation design verification
【24h】

Electrical testing of large scale IR&D dummy coil for TPX magnet insulation design verification

机译:用于TPX磁体绝缘设计验证的大型IR&D虚拟线圈的电气测试

获取原文
获取原文并翻译 | 示例

摘要

Electrical test results are reported characterizing the dielectric properties, insulation capability, and equivalent circuit parameters of a 1.8 m OD, 24 turn IR&D dummy coil built by the Westinghouse TPX Team to address magnet coil manufacturing issues and to verify electrical insulation design for TPX PF and TF magnet coils. Induced voltage tests at 77 K were performed at the National High Magnetic Field Laboratory (NHMFL) to 200 V per turn without dielectric failure. High voltage testing was performed at Everson Electric under room temperature factory conditions. The coil turn insulation was surge tested to 21 kV without failure. The coil groundwall insulation was hipot tested up to 58 kV with 48 kV minimum withstand to the imbedded groundplane screen electrode. The coil was sectioned and examined for insulation impregnation quality and manufacturing tolerances.
机译:报告了电气测试结果,这些结果表征了由西屋TPX团队制造的1.8 m OD,24匝IR&D虚拟线圈的介电性能,绝缘能力和等效电路参数,以解决电磁线圈制造问题并验证TPX PF和TF电磁线圈。在国家高磁场实验室(NHMFL)进行的感应电压测试为77 K,每转200 V,无电介质故障。高压测试是在Everson Electric在室温下的工厂条件下进行的。线圈匝绝缘经浪涌测试至21 kV,无故障。线圈接地壁绝缘层经过高压测试,最高电压为58 kV,最小承受嵌入式接地屏蔽电极的电压为48 kV。对该线圈进行切片并检查绝缘浸渍质量和制造公差。