70 MW class superconducting generators are under development as a national project in Japan. This is an eleven-year program which commenced in 1988. The manufacturing of the slow response excitation type rotor was completed at the beginning of 1996, and performance test of the rotor was carried out in the factory at the beginning of 1997. The factory test has been completed successfully. This paper describes the factory test results of the cryogenic performance and the electrical performance
机译:70兆瓦级超导发电机正在日本作为国家项目进行开发。这是一个从1988年开始的为期11年的计划。慢响应励磁型转子的制造于1996年初完成,并且转子的性能测试已于1997年初在工厂进行了测试。已成功完成。本文介绍了低温性能和电气性能的出厂测试结果