首页> 外文期刊>IEEE Transactions on Applied Superconductivity >Design and test results of 6.6 kV high-Tc superconducting faultcurrent limiter
【24h】

Design and test results of 6.6 kV high-Tc superconducting faultcurrent limiter

机译:6.6 kV高Tc超导故障限流器的设计和测试结果

获取原文
获取原文并翻译 | 示例

摘要

A 6.6 kV single-phase fault current limiter (FCL) using a high-Tc superconducting coil as a limiting coil was developed. The development is a preliminary step to investigate the feasibility of the FCL application for high-voltage transmission lines. The FCL is of the rectifier type and is mainly comprised of a limiting coil, a sub-cooled nitrogen cryostat with a cryocooler, and a rectifier bridge. The limiting coil, wound as a solenoid by Ag/Mn sheathed Bi-2223 tapes, has an inductance of 30 mH. It is immersed in a liquid nitrogen bath in the cryostat. A Gifford-McMahon cryocooler cools the cryogen below 77.3 K. A pressure regulator keeps the cryogen at an atmospheric pressure. The coil has a critical current of 70 A at 64 K and endures a 50 Hz overvoltage of 22 kV against the ground. In a fault current limiting test with a short-circuit generator, a short-circuit current of 12.5 kA was limited to 1.2 kA
机译:开发了使用高Tc超导线圈作为限制线圈的6.6 kV单相故障电流限制器(FCL)。该开发是研究FCL在高压输电线路中应用可行性的初步步骤。 FCL是整流器类型的,主要由限流线圈,带低温冷却器的过冷氮气低温恒温器和整流桥组成。限位线圈由Ag / Mn包覆的Bi-2223带缠绕成螺线管,电感为30 mH。将其浸入低温恒温器的液氮浴中。 Gifford-McMahon制冷机将制冷剂冷却到77.3 K以下。压力调节器将制冷剂保持在大气压下。线圈在64 K时具有70 A的临界电流,并且相对于地面可承受22 kV的50 Hz过电压。在使用短路发生器的故障电流限制测试中,将12.5 kA的短路电流限制为1.2 kA