首页> 外文期刊>IEEE Transactions on Applied Superconductivity >Resistances of electrical joints in the TF model coil of ITER: comparisons of first test results with samples results
【24h】

Resistances of electrical joints in the TF model coil of ITER: comparisons of first test results with samples results

机译:ITER TF模型线圈中电接头的电阻:首次测试结果与样品结果的比较

获取原文
获取原文并翻译 | 示例

摘要

The test of the Toroidal Field (TF) Model Coil of the International Thermonuclear Experimental Reactor (ITER) has been the opportunity to measure the DC resistances of all the joints of a real coil and to compare them to values previously measured on prototype full-size joint samples. This paper describes and discusses the different methods used for measuring all the joint resistances, and gives the results of joint resistance measurements (1-2 n/spl Omega/ range) as function of the coil current up to the maximum value of 80 kA. Comparisons with resistances measured on prototype joints in relevant field/current conditions are presented and discussed.
机译:国际热核实验堆(ITER)的环形场(TF)模型线圈的测试提供了一个机会,可以测量真实线圈的所有接头的直流电阻,并将它们与以前在原型全尺寸上测得的值进行比较联合样本。本文描述并讨论了用于测量所有接头电阻的不同方法,并给出了接头电阻测量结果(1-2 n / spl Omega /范围),该结果取决于最大电流为80 kA的线圈电流。提出并讨论了与在相关的现场/电流条件下在原型接头上测得的电阻的比较。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号